beautypg.com

8 gv-cloud access control integration – GeoVision GV-R1352 Card Reader (13.56 MHz) User Manual

Page 79

background image

70

8.8 GV-Cloud Access Control Integration

The GV-DFK1355 reader, which has two inputs (Exit Button and Door Sensor) and one

output (Door Lock), can control a single door when combined with the GV-AS Bridge

controller and the cloud-based software GV-Cloud Access Control.

Note:

GV-AS Bridge and GV-Cloud Access Control are coming soon.

GV-AS Bridge

(controller)

GV-Cloud Access Control

(cloud-based SW)

GV-DFK1355

(reader)

RS-485

Internet

Up to 8 readers

The RS-485 interface on GV-AS Bridge can support up to 8 readers. When connecting

multiple readers, you must assign each one a unique ID so that GV-AS Bridge can recognize

them. For how to configure the reader

’s ID, see

8.7 ID, DESFire and GID Settings

.

Input 1

of the reader is for a Door Sensor with NC (Normal Closed) and

Input 2

is for an Exit

Button with NO (Normal Open); neither of these settings can be changed. The reader's

Relay

is made for a Door Lock, and you can switch between NO and NC by using the

reader's switch. See

8.3 Physical Descriptions

.

Note:

Based on the connected output (Door Lock) on GV-DFK1355, only the door alarm

statuses "Held Open", "Force Open", and

“Lockdown” are available on GV-Cloud Access

Control.

Force Open

When "Force Open" is enabled on the reader, it will continue to beep, and the alarm

status can only be cleared using GV-Cloud Access Control, or swipe a valid access
card.

Held Open

The

“Held Open” alarm is generated when Held Open Time expires, which begins to

countdown when the door lock is engaged but the door remains open.

When the

“Held Open” alarm is generated, the reader will continue to beep until the

door is closed.