beautypg.com

3 define readers on gv-as controller web interface – GeoVision GV-R1352 Card Reader (13.56 MHz) User Manual

Page 28

background image

GV-RK1352 / R1352 / DFR1352

19

2

2.3.3 Define Readers on GV-AS Controller Web Interface

Since multiple readers can connect to GV-AS Controller using one RS-485 interface, you

need to specify which door each reader controls. This section explains how to define readers

on the Web interface of GV-AS Controller. On the Web interface, you can also set the reader

to read the GID or UID on your card / fob. Note that the Web interface of different GV-AS

Controller models varies.

1. On the controller

’s Web interface, click

Extended Reader

. This dialog box appears.

2. In the GV-Reader/CR420/GF1921/GF1922 section, select the

RS485

checkbox in front of

the ID number and type the

Serial Number

on the rear panel of the reader. The ID

number will be assigned to the reader.

GV-R1352

Red

7.5V~12VDC

Black

GND

Green

Wiegand Data 0

White

Wiegand Data 1

Blue

RS-485+

L Blue

RS-485-

A

B

C

D

Yellow

Beeper

Orange

Green LED

L Red

Red LED

Brown

N/A

Purple

N/A

Gray

N/A

© 2011 GeoVision, Inc. All rights reserved.
All GeoVision Products are made in Taiwan.

666666666666

V1

V2

3. Select a door/gate for the reader from the

Function

drop-down list.