Index – ProSoft Technology MVI56-PDPMV1 User Manual
Page 253

MVI56-PDPMV1 ♦ ControlLogix Platform
Index
PROFIBUS DPV1 Master
User Manual
ProSoft Technology, Inc.
Page 253 of 255
March 22, 2011
Index
A
About the PROFIBUS Protocol • 201
Acyclic Message Status Word • 151, 154, 156, 157,
158, 161, 162, 164, 173
Adding Multiple Modules (Optional) - Flex • 56
Adding Multiple Modules (Optional) - Legacy • 30
Adding MVI56-PDPMV1 Logic To Existing Applications
• 35
Adjusting the Connection Sizes for Your Application •
39, 41, 70
Allocation of Risks • 252
B
Backing Up the Project • 109
Basic Troubleshooting Steps • 178
Battery Life Advisory • 3
Block ID Numbers for Transfer • 230, 237
Bus Access • 201
Byte 0 - Station Status 1 Bits • 195
Byte 1 - Station Status 2 Bits • 195
Byte 2 - Station Status 3 Bits • 196
Byte 3 - Master Address • 196
Byte 4 - Ident Number High • 196
Byte 5 - Ident Number Low • 196
C
Changing and Importing Configuration Changes (for
PCB v 2.2.0 and up only) • 72, 109
Checking the comDTM Install Version • 224
Checking the comDTM Version • 224
Checking the Install Version for Vista • 226
Checking the PROFIBUS LEDs on the MVI56-
PDPMV1 • 123
Choosing Sample Ladder Logic For Your Application •
16, 36
Choosing the Controller Type • 65
CIP Generic Messages • 244
CIP Message Support • 244
Common Settings for All Sample Programs • 23, 65
Configuring the MVI56-PDPMV1 Module • 79
Configuring the PROFIBUS Master • 79, 84
Configuring the PROFIBUS Slaves • 86, 104, 129, 131
Connecting the comDTM to the Master to Establish
Communication • 216
Connecting Your PC to the Module • 77
Constructing a Bus Cable for PROFIBUS DP • 204
Contacting Technical Support • 245, 247
Controlling Law and Severability • 252
COP Instruction (input) • 43
COP Instruction (output) • 44
Creating a New RSLogix5000 Project • 49
Creating a New RSLogix5000 Project - Legacy • 25
Creating the Module - Legacy • 23, 25
Creating the MVI56-PDPMV1 Module Profile - Flex •
23, 50
D
DB9 to RJ45 Adaptor (Cable 14) • 186
Determining the Firmware Version of the MVI56-
PDPMV1 Module • 18, 179
Determining the Firmware Version of Your Processor •
17
Determining the Module Mode (LEGACY or FLEX) •
20, 179
Diagnostics and Troubleshooting • 9, 177
Disabling the RSLinx Driver for the Com Port on the
PC • 184
Disclaimer of all Other Warranties • 251
Disclaimer Regarding High Risk Activities • 250
Displaying the Current Page of Registers Again • 192,
194
Downloading the Project to the Module • 79, 111
Downloading the Sample Program to the Processor •
76
DP-V1 Error Codes • 176
E
Error Codes • 174, 175
Example • 222
Example - FLEX application • 44
Example - GetSlaveConfiguration Mailbox • 140
Example 1
Local Rack Application • 113
Example 2
Remote Rack Application • 117
Examples • 180
Exiting the Program • 192
Exporting the Processor Files for PCB v2.2.0 or later •
16, 72, 75, 107
Exporting the Processor Files Prior to PCB v2.2.0 • 27,
41, 105
F
Flex Mode (Use Legacy Mode=No) • 183
Flex Mode Input and Output Data Blocks • 229, 236
Flex Mode Mailbox Communication • 135
FLEX Sample Add-On Instruction Import Procedure •
38
Flexible Connection I/O Length Overview • 38
Functional Specifications • 199
G
General Specifications • 198
Guide to the MVI56-PDPMV1 User Manual • 9
H
Hardware Requirements (Recommended) • 212
Hardware Specifications • 199
How Cable Length Affects Communication Rate • 202