beautypg.com

11 utility function, 1 display system firmware version, Utility function -10 – KEPCO KLP Series (older -1200 models) Operator Manual User Manual

Page 50: Display system firmware version -10

background image

3-10

KLP073008

• If analog control is used, only the master is configured for analog control (the slave is

controlled digitally by the master).

• If Remote Inhibit is used, it should only be connected to the master.

• If E241 (hardware error) is showing in the status display, the FUNCTION switch can be

used to change the configuration

• If there is no communication between units for approximately 10 seconds, all units will

turn off their output and the status display will flash E241 (hardware error), then xOFy
where x = unit number and y = total number of units, and finally the serial/parallel config-
uration setting SERI or PARA.

3.2.11

UTILITY FUNCTION

The Utility Function provides additional system information or access to special functions.
These are:

VERS - Display System Firmware Version (see PAR. 3.2.11.1)

MODL - Display Model (see PAR. 3.2.11.2)

RELY - Relay Control

QkBT - Quick Boot

INVC - Analog Input Voltage and Current A to D calibration voltages (see PAR. 3.2.11.5)

LBT - Loop Back Test used to isolate RS 232 communication problems (see PAR.

3.4.2.4.

CAL - Display last calibration date and/or begin Calibration (see PAR. 3.2.11.6)

1. If the status display shows SET, tap either the CURRENT or VOLTAGE controls to take the

unit out of setpoint mode (status display goes from SET to blank)

2. Using a thin tool (e.g., a paper clip), press the FUNCTION switch repeatedly until the status

display shows UTIL. Press the DC OUTPUT switch to enter the UTIL Menu.

3. Rotate either the VOLTAGE or CURRENT control in either direction to select the function as

identified in the status display as listed above (clockwise selects the functions in the order
described below, counterclockwise reverses the order).

3.2.11.1

DISPLAY SYSTEM FIRMWARE VERSION

Enter UTIL menu and rotate either VOLTAGE or CURRENT control until status display reads
VERS (see PAR. 3.2.11).

• The DC VOLTS display identifies whether the firmware is the factory shipped firmware

(Pri displayed) or field updated firmware (SEC displayed).

• The DC AMPS display shows the firmware version.

This manual is related to the following products: