KLP 073008

1-5

PROGRAMMING CHARACTERISTICS - ANALOG

Analog remote control

selection Activate with jumper at analog program-

ming connector

Recognized during power up.

isolation Safety Extra Low Voltage (SELV)

referenced to chassis

Programming by voltage

voltage 0-10V

Programmable

current minimal value-10V

Programming by resistance

voltage 0-10K ohms

Programmable

current 0-10K ohms

Readback

0-10V proportional signal

Proportional to analog control volt-
age/resistance

Remote inhibit

TTL compatible

Composite status flag

Isolated form C contacts

Programmable functions (PAR. 2.7.10)

Programming time

20 milliseconds

10% to 90% E

out

PROGRAMMING CHARACTERISTICS - DIGITAL

Digital remote control

isolation Safety Extra Low Voltage (SELV)

referenced to chassis

format compatible with SCPI protocols

W95, W98 and NT operating systems

Programming resolution

0.024% of Emax and Ilim

Programming accuracy

0.05% of Emax and Ilim

Readback resolution

0.024% of Emax and Ilim

Readback accuracy

0.1% of Emax and Ilim

Status reporting

OVP, OCP, OTP, output lead fault
(OLF), fan failure, power loss

See PAR. 1.4.4 and 1.4.9

NOTES:
(1) Requires the a-c input to be recycled for restart
(2) OVP and OCP limit adjustment is disabled in Remote Analog Mode

TABLE 1-2. KLP SPECIFICATIONS (Continued)

SPECIFICATION

RATING/DESCRIPTION

CONDITION