B-14

KLP 073008

FIGURE B-5. PROGRAMMING AS VOLTAGE STABILIZER

B.56 [SOURce:]VOLTage:[:LEVel]TRIGgered[:AMPlitude]? QUERY

VOLT:TRIG?

Syntax:

Short Form: [SOUR:]VOLT[:LEV]:TRIG[:AMP]?
Long Form: [SOURce:]VOLTage[:LEVel]:TRIGgered[:AMPlitude]?
Return Value: = digits with decimal point and Exponent, e.g., 2.71E+1 for 27.1

Description: Returns value representing voltage value to be programmed by *TRG command established by

VOLT:TRIG command). (See example, Figure B-1.)

B.57 STATus:OPERation:CONDition QUERY

STAT:OPER:COND?

Syntax:

Short Form: STAT:OPER:COND?

Long Form: STATus:OPERation:CONDition?

Return Value: 0 to 1313 (1 + 32 + 256 + 1024).

Description: Returns the value of the Operation Condition Register (see Table B-2). The Operation Condition

Register contains unlatched real-time information about the operating conditions of the power supply.
Bit set to 1 = function enabled (active, true); bit reset to 0 = function disabled (inactive, false). (See
example, Figure B-6.)

NOTE: The following example assumes KLP 75-33-1200 with virtual model set for 36V, 33.33A and

output operating in voltage stabilization mode. See Figure B-3 for directions on programming
virtual model limits.

VOLT 21.8;CURR .5

Programs output voltage for 21.8V, output current for 0.5A.

OUTP ON

Enables output. NOTE: Load determines output operating mode; if

load resistance is greater than 21.8/0.5, output will operate as
voltage stabilizer.

MEAS:VOLT?

Returns measured output voltage, approximately 2.18E1 (21.8V)

assuming voltage stabilizer operation.

VOLT?

Returns 2.18E1 ( (21.8V, programmed output voltage).

VOLT 2.15

Programs output voltage to 2.15V.

VOLT?

Returns 2.15E0 (2.15V, programmed output voltage).

VOLT? MAX

Returns 3.6E1 (36V, the virtual model voltage setting).

VOLT? MIN

Returns 0 (minimum allowable program voltage).

VOLT:PROT 6.5

For this model, minimum overvoltage protection is 0.2 x 75 = 15V,

therefore power supply returns error message -222 (Data out of
range, ESR bit 4 =1) and the limit remains unchanged.

VOLT:PROT 25

Sets overvoltage protection limit to 25V.

VOLT:PROT?

Returns 2.5E1 (25V).

VOLT 26

Returns error message -301 (Value bigger than limit, ESR bit 3=1)

and current setting remains unchanged at 2.15V.

VOLT:PROT?MAX

Returns 9E1 (maximum allowable overvoltage protection limit for

model is 90V, 20% above maximum voltage (75V) for KLP 75-33-
1200, regardless of virtual model setting).

TABLE B-2. OPERATION CONDITION REGISTER, OPERATION ENABLE REGISTER,

AND OPERATION EVENT REGISTER BITS

CONDITION

NU

PR

NU

CC

NU

CV

NU

WTG

NU

CAL

BIT

15

14

11-13

10

9

8

7 - 6

5

4 - 1

0

VALUE

32,768 16,384

2048 -

8192

1024 512

256

128
- 64

32

16 -

2

1

CAL - INTERFACE COMPUTING NEW CALIBRATION

CONSTANTS

CC -

POWER SUPPLY IN CONSTANT CURRENT
MODE

CV -

POWER SUPPLY IN CONSTANT VOLTAGE
MODE

NU -

NOT USED

PR -

PROGRAM RUNNING

WTG - WAIT FOR TRIGGER (SET BY TRIG

SUBSYSTEM)