TABLE 1-2. KLP SPECIFICATIONS

SPECIFICATION

RATING/DESCRIPTION

CONDITION

INPUT CHARACTERISTICS

a-c voltage

nominal

110-240 Va-c

Single Phase

range

100-255 Va-c

Wide Range; contact factory for opera-
tion to 265V a-c.

d-c voltage

range

125-420 Vd-c

No regulatory agency approval

Frequency

nominal range

50-60 Hz

maximum

45-440 Hz

Increased Leakage above 66 Hz

Power Factor

typical

0.99

meets EN 61000-3-2

Maximum Input Current

120 Va-c

13A rms

Rated load (1200W)

240 Va-c

6.5A rms

Rated load (1200W)

Inrush Current

265 Va-c

40A

Peak

132 Va-c

20A

Peak

Input Fusing

Circuit Breaker

2-line

Low a-c Protection

Self protected

No Fixed Limits

Output hold up

typical

10 milliseconds

Ride Through

Leakage Current

115 Va-c, 60Hz

5mA

230 Va-c 50Hz

10mA

OUTPUT CHARACTERISTICS

Type of stabilizer

CV/CL

Voltage/Current

Adjustment range

voltage

0-100% of rated voltage

no minimum load required

current

0-100% of rated current

no minimum load required

Source effect

voltage

0.01% Emax

over full source range

current

0.01% Imax

Load effect

voltage

0.01% Emax

over full load current range

current

0.02% Imax

Temperature effect

voltage

0.02%/deg C

0-50 deg C

current

0.05%/deg C

Time effect (drift)

voltage

0.05%/24hr

after 30 min warmup

current

0.05%/24hr

Error sensing

0.25 volts per wire

above rated output

Isolation voltage

600 Vd-c or peak

either output terminal to ground

Transient recovery
for load change

excursion

1% of Emax

50% load step 2A/microsecond max

recovery

0.2 msec

return to 0.1% of setting

Turnon/turnoff overshoot

same as load transient response limits

Overvoltage protection

voltage

programmable

latched

(1)

Overcurrent protection

current

programmable

latched

(1)

Overtemperature protection

Shutdown

latched

(1)

Open Load wire protection

Shutdown

latched

(1)

Parallel operation

Active load sharing within 5% of Io rated Up to 5 units, maximum