Transmitter Supply Voltage Selection (P+, P-)
All controllers, including models equipped with the 12/24 VDC power 
option, are shipped from the factory configured to provide 24 VDC 
power for the transmitter or sensor. 
If the transmitter requires 5 or 10 VDC excitation, the internal jumper 
J4 must be configured accordingly. 
To access the voltage selection jumper: 
1. Remove all the connectors. 
2. Unscrew the back cover. 
3. Slide the back cover about 1 inch. 
4. Configure the J4 jumper, located behind the input signal connector, 
for the desired excitation voltage as shown.
MAIN BOARD
INPUT
SIGNAL
J4
5 V
10 V
24 V
J4 CONFIGURATION
Factory Default
P+
P-
mA+
COM
V+
Figure 5: Transmitter Supply Voltage Selection
Connections
All connections are made to removable screw terminal connectors 
located at the rear of the controller. 
!
Caution!
Use copper wire with 60°C or 60/75°C insulation for 
all line voltage connections. Observe all safety regu-
lations. Electrical wiring should be performed in ac-
cordance with all applicable national, state, and local 
codes to prevent damage to the controller and en-
sure personnel safety. 