Transmitter supply voltage selection (p+, p-), Connections – Precision Digital PD6310 User Manual
Page 21
Model PD6210 & PD6310 Batch Controllers
Instruction Manual
21
Transmitter Supply Voltage Selection (P+, P-)
All controllers, including models equipped with the 12/24 VDC power
option, are shipped from the factory configured to provide 24 VDC
power for the transmitter or sensor.
If the transmitter requires 5 or 10 VDC excitation, the internal jumper
J4 must be configured accordingly.
To access the voltage selection jumper:
1. Remove all the connectors.
2. Unscrew the back cover.
3. Slide the back cover about 1 inch.
4. Configure the J4 jumper, located behind the input signal connector,
for the desired excitation voltage as shown.
MAIN BOARD
INPUT
SIGNAL
J4
5 V
10 V
24 V
J4 CONFIGURATION
Factory Default
P+
P-
mA+
COM
V+
Figure 5: Transmitter Supply Voltage Selection
Connections
All connections are made to removable screw terminal connectors
located at the rear of the controller.
!
Caution!
Use copper wire with 60°C or 60/75°C insulation for
all line voltage connections. Observe all safety regu-
lations. Electrical wiring should be performed in ac-
cordance with all applicable national, state, and local
codes to prevent damage to the controller and en-
sure personnel safety.