3.6 Wiring MECHATROLINK-III Communications
3-33
3
Wi
ring and
C
onne
ctio
n
3.6 Wiring MECHATROLINK-III Communications
The following diagram shows an example of connections between a host controller and a
SERVOPACK.
Connect the MECHATROLINK-III communications cables to the CN6A and CN6B on the SERVOPACK as
shown below.
Note: The length of the cable between stations (L1, L2 ... Ln) must be 75 m maximum.
For removing the MECHATROLINK-III communications cable connectors from the SERVOPACK, refer to the following
procedure.
Slide the lock injector of the connector to the SERVOPACK side to unlock and remove the MECHATROLINK-III com-
munications cable connectors.
Note: The MECHATROLINK-III communications cable connector may be damaged if it is removed without being
unlocking.