Yaskawa Sigma-5 Large Capacity Users Manual: Design and Maintenance-Rotary Motors-Mechatrolink-III Communication Reference User Manual
Page 53
3.1 Main Circuit Wiring
3-7
3
Wi
ring and
C
onne
ctio
n
For Three-phase, 400V
∗1. Use SERVOPACKs and converters in the specified combinations.
∗2. Use the crimp terminals that are recommended by Yaskawa or an equivalent.
Combination of SERVO-
PACK and Converter
*1
Terminal
Symbols
Screw Size
for Terminals
Tightening
Torque
(N m)
HIV Wire Size
in mm
2
(AWG)
Crimp Terminal
Model
(Made by J.S.T.
Mfg Co., Ltd.)
*2
SGDV-750J
SGDV-
COA3ZDA
SERVO-
PACK
P, N
M8
15.0
Bus bar attached
to the converter
–
U, V, W
M8
3.0
22 (4)
R22-8
DU, DV, DW
M6
3.0
3.5 (12)
3.5-6
M8
9.0 to 11.0
22 (4)
R22-8
Converter
P, N
M8
3.0
Bus bar attached
to the converter
–
L1, L2, L3
M8
3.0
22 (4)
R22-8
1, 2
M8
3.0 22
(4)
R22-8
CN101
(24 V, 0 V)
–
(Connector)
–
1.25 (16)
–
B1, B2
M8
3.0
8 (8)
R8-8
M8
9.0 to 11.0
22 (4)
R22-8
SGDV-101J
SGDV-
COA5EDA
SERVO-
PACK
P, N
M8
15.0
Bus bar attached
to the converter
–
U, V, W
M8
3.0
38 (1)
R38-8
DU, DV, DW
M6
3.0
3.5 (12)
3.5-6
M8
9.0 to 11.0
38 (1)
R38-8
Converter
P, N
M10
12 to 20
Bus bar attached
to the converter
–
L1, L2, L3
M10
12 to 20
38 (1)
R38-10
1, 2
M10
12 to 20
38 (1)
R38-10
CN101
(24 V, 0 V)
–
(Connector)
–
1.25 (16)
–
B1, B2
M10
12 to 20
8 (8)
R8-10
M8
9.0 to 11.0
38 (1)
R38-8
SGDV-131J
SGDV-
COA5EDA
SERVO-
PACK
P, N
M10
12 to 20
Bus bar attached
to the converter
–
U, V, W
M10
30.0
60 (2/0)
R60-10
DU, DV, DW
M6
3.0
3.5 (12)
3.5-6
M8
9.0 to 11.0
60 (2/0)
R60-8
Converter
P, CN
M10
12 to 20
Bus bar attached
to the converter
–
L1, L2, L3
M10
12 to 20
60 (2/0)
R60-10
1, 2
M10
12 to 20
60 (2/0)
R60-10
CN101
(24 V, 0 V)
–
(Connector)
–
1.25 (16)
–
B1, B2
M10
12 to 20
14 (6)
R14-10
M8
9.0 to 11.0
60 (2/0)
R60-8