10 Appendix

10-52

Pn601

0

Dynamic Brake Resistor Capacity

Immediately

Pn800

1040

Communications Control

Immediately

Pn801

0003

Application Function Select 6
(Software LS)

Immediately

Pn803

10

Origin Range

Immediately

Pn804

1073741823

Forward Software Limit

Immediately

Pn806

-1073741823

Reverse Software Limit

Immediately

Pn808

0

Absolute Encoder Origin Offset

Immediately

∗2

Pn80A

100

1st Linear Acceleration Constant

Immediately

∗3

Pn80B

100

2nd Linear Acceleration Constant

Immediately

∗3

Pn80C

0

Acceleration Constant Switching
Speed

Immediately

∗3

Pn80D

100

1st Linear Deceleration Constant

Immediately

∗3

Pn80E

100

2nd Linear Deceleration Constant

Immediately

∗3

Pn80F

0

Deceleration Constant Switching
Speed

Immediately

∗3

Pn810

0

Exponential Function Acceleration/
Deceleration Bias

Immediately

∗3

Pn811

0

Exponential Function Acceleration/

Deceleration Time Constant

Immediately

∗3

Pn812

0

Movement Average Time

Immediately

∗3

Pn814

100

Final Travel Distance for External
Positioning

Immediately

∗3

Pn816

0000

Homing Mode Setting

Immediately

∗3

Pn817

50

Homing Approach Speed
(Homing Approach Speed 1)

Immediately

∗3

Pn818

5

Homing Creep Speed
(Homing Approach Speed 2)

Immediately

∗3

Pn819

100

Final Travel Distance for Homing

Immediately

∗3

Pn81E

0000

Input Signal Monitor Selection

Immediately

Pn81F

0010

Command Data Allocation

After restart

Pn820

0

Forward Latching Allowable Area

Immediately

Pn822

0

Reverse Latching Allowable Area

Immediately

Pn824

0000

Option Monitor 1 Selection

Immediately

Pn825

0000

Option Monitor 2 Selection Immediately

Pn827

100

Linear Deceleration Constant 1 for
Stopping

Immediately

∗3

Pn829

0

SVOFF Waiting Time (SVOFF at
deceleration to stop)

Immediately

Pn82A

1813

Option Field Allocation 1

After restart

∗2. Available after the SENS_ON command is input.

∗3. Change the setting when the reference is stopped (DEN is set to 1), because the change will affect the output during

operation.

Note: When using parameters that are enabled after restarting the SERVOPACK, a CONFIG command must be input or

the power must be turned OFF and then ON again.

(cont’d)

Parameter

Factory

Setting

Name

When

Enabled