2 mechatrolink-iii commands, 4 (2) settings of the dip switch s3 – Yaskawa Sigma-5 Large Capacity Users Manual: Design and Maintenance-Rotary Motors-Mechatrolink-III Communication Reference User Manual

Page 100

background image

4 Operation

4.1.1 Setting Switches S1, S2, and S3

4-4

(2) Settings of the DIP Switch S3

The following table shows the settings of the DIP switch (S3).

4.2 MECHATROLINK-III Commands

For information on the MECHATROLINK-III commands, refer to

Σ

-V Series User’s Manual MECHA-

TROLINK-III Standard Servo Profile Commands (SIEP S800000 63).

S3

Function

Setting

Factory

setting

Pins 1 and 2

Sets the number of

transmission bytes.

1

2

Number of transmission bytes

1: OFF

2: ON

OFF

OFF

16 byte

ON

OFF

32 byte

OFF

ON

48 byte

ON

ON

Reserved.
(Do not use this setting.)

Pin 3

Reserved. (Do not change.)

OFF

Pin 4

Reserved. (Do not change.)

OFF

• When using the MECHATROLINK-III standard servo profile, set the number of transmis-

sion bytes to either 32 or 48.

• When using the MECHATROLINK-II-compatible profile, set the number of transmission

bytes to either 16 or 32.

• Turn the power OFF and then ON again to enable the new settings.