10.1 List of Parameters

10-7

10

Ap

pend

ix

Pn00B

2

Application Function Select
Switch B

0000 to 1111

0000

After restart

Setup

Pn00C

2

Application Function Select
Switch C

0000 to 0111

0000

After restart

Setup

4.5,

4.5.1

(cont’d)

Parameter

No.

Size

Name

Setting

Range

Units

Factory

Setting

When

Enabled

Classi-

fication

Profile

Reference

Section

Parameter Display Selection

Reference

Section

0

Setup parameters

2.4.1

1

All parameters

Alarm Gr.2 Stop Method Selection

Reference

Section

0

Stops the motor by setting the speed reference to "0".

4.3.5

1

Same setting as Pn001.0 (Stops the motor by applying DB or by coasting).

Reserved (Do not change.)

Reserved (Do not change.)

4th 3rd 2nd 1st

digit digit digit digit

n.

Selection of Test without a Motor

0

Disables test without a motor.

1

Enables test without a motor.

Encoder Resolution for Test without a Motor

0

13 bits

1

20 bits

Encoder Type for Test without a Motor

0

Incremental encoder

1

Absolute encoder

Reserved (Do not change.)

4th 3rd 2nd 1st

digit digit digit digit

n.