Yaskawa Sigma-5 Large Capacity Users Manual: Design and Maintenance-Rotary Motors-Mechatrolink-III Communication Reference User Manual
Page 370
10.1 List of Parameters
10-21
10
Ap
pend
ix
Pn511
2
Input Signal Selection 5
0000 to
FFFF
−
6541
After restart
Setup
−
3.4.1
(cont’d)
Parameter
No.
Size
Name
Setting
Range
Units
Factory
Setting
When
Enabled
Classi-
fication
Profile
Reference
Section
Homing Deceleration Switch Signal Mapping (/DEC)
0
Active when CN1-40
input signal is ON (closed).
1
Active when CN1-41
input signal is ON (closed).
2
Active when CN1-42
input signal is ON (closed).
3
Active when CN1-43
input signal is ON (closed).
4
Active when CN1-44
input signal is ON (closed).
5
Active when CN1-45 input signal is ON (closed).
6
Active when CN1-46 input signal is ON (closed).
7
Always active (fixed).
8
Not active (fixed).
9
Active when CN1-40 input signal is OFF (open).
A
Active when CN1-41 input signal is OFF (open).
B
Active when CN1-42
input signal is OFF (open).
C
Active when CN1-43
input signal is OFF (open).
D
Active when CN1-44 input signal is OFF (open).
E
Active when CN1-45 input signal is OFF (open).
F
Active when CN1-46
input signal is OFF (open).
External Latch Signal Mapping (/EXT1)
4
Active when CN1-10 input signal is ON (closed).
5
Active when CN1-11 input signal is ON (closed).
6
Active when CN1-12 input signal is ON (closed).
7
Always active (fixed).
8
Not active (fixed).
D
Active when CN1-10 signal is OFF (open).
E
Active when CN1-11 signal is OFF (open).
F
Active when CN1-12 signal is OFF (open).
0 to 3
9 to C
Not active (fixed).
External Latch 2 Signal Mapping (/EXT2)
4 to 8
D to F
Same as /EXT1 signal mapping.
External Latch 3 Signal Mapping (/EXT3)
4 to 8
D to F
Same as /EXT1 signal mapping.
4th 3rd 2nd 1st
digit digit digit digit
n.