Yaskawa Sigma-5 Large Capacity Users Manual: Design and Maintenance-Rotary Motors-Mechatrolink-III Communication Reference User Manual
Page 360
10.1 List of Parameters
10-11
10
Ap
pend
ix
Pn143
2
Model Following Control
Bias
(Forward Direction)
0 to 10000
0.1%
1000
Immediately
Tuning
−
−
Pn144
2
Model Following Control
Bias
(Reverse Direction)
0 to 10000
0.1%
1000
Immediately
Tuning
−
−
Pn145
2
Vibration Suppression 1
Frequency A
10 to 2500
0.1 Hz
500
Immediately
Tuning
−
−
Pn146
2
Vibration Suppression 1
Frequency B
10 to 2500
0.1 Hz
700
Immediately
Tuning
−
−
Pn147
2
Model Following Control
Speed Feedforward
Compensation
0 to 10000
0.1%
1000
Immediately
Tuning
−
−
Pn148
2
2nd Model Following Control
Gain
10 to 20000
0.1/s
500
Immediately
Tuning
−
−
Pn149
2
2nd Model Following Control
Gain Compensation
500 to 2000
0.1%
1000
Immediately
Tuning
−
−
Pn14A
2
Vibration Suppression 2
Frequency
10 to 2000
0.1 Hz
800
Immediately
Tuning
−
−
Pn14B
2
Vibration Suppression 2
Compensation
10 to 1000
1%
100
Immediately
Tuning
−
−
Pn14F
2
Control Related Switch
0000 to 0011
-
0011
After restart
Tuning
−
–
(cont’d)
Parameter
No.
Size
Name
Setting
Range
Units
Factory
Setting
When
Enabled
Classi-
fication
Profile
Reference
Section
Model Following Control Type Selection
Reference
Section
0
Model Following Control 1
5.3.1,
5.4.1,
5.5.1
1
Model Following Control 2
Tuning-less Type Selection
Reference
Section
0
Tuning-less type 1
5.2.2
1
Tuning-less type 2
Reserved (Do not change.)
Reserved (Do not change.)
4th 3rd 2nd 1st
digit digit digit digit
n.