Yaskawa R1000 Series Power Regenerative Unit User Manual
Page 216

D.3 UL Standards
216
YASKAWA ELECTRIC TOEP C710656 08B YASKAWA Power Regenerative Unit - R1000 Instruction Manual
Note: Use crimp insulated terminals or insulated shrink tubing for wiring connections. Wires should have a continuous maximum
allowable temperature of 75
°C 600 Vac UL-approved vinyl-sheathed insulation.
4A0150
–
3/0
×
2P
M12
80-L12
YF-1
YET-300-1
TD-323
TD-312
TP-080
100-051-558
–
4/0
×
2P
100-L12
YF-1
YET-300-1
TD-324
TD-312
TP-100
100-051-560
250
250
×
2P
150-L12
YF-1
YET-300-1
TD-325
TD-313
TP-150
100-051-562
300
300
×
2P
150-L12
YF-1
YET-300-1
TD-325
TD-313
TP-150
100-051-562
–
350
×
2P
200-L12
YF-1
YET-300-1
TD-327
TD-314
TP-200
100-051-564
–
400
200-L12
YF-1
YET-300-1
TD-327
TD-314
TP-200
100-051-564
–
500
325-12
YF-1
YET-300-1
TD-328
TD-315
TP-325
100-051-277
–
600
325-12
YF-1
YET-300-1
TD-328
TD-315
TP-325
100-051-277
4A0210
3/0
× 2P
–
M12
80-L12
YF-1
YET-300-1
TD-323
TD-312
TP-080
100-051-558
4/0
× 2P
100-L12
YF-1
YET-300-1
TD-324
TD-312
TP-100
100-051-560
250
× 2P
150-L12
YF-1
YET-300-1
TD-325
TD-313
TP-150
100-051-562
300
× 2P
150-L12
YF-1
YET-300-1
TD-325
TD-313
TP-150
100-051-562
350
× 2P
200-L12
YF-1
YET-300-1
TD-327
TD-314
TP-200
100-051-564
400
400
× 2P
200-L12
YF-1
YET-300-1
TD-327
TD-314
TP-200
100-051-564
500
500
× 2P
325-12
YF-1
YET-300-1
TD-328
TD-315
TP-325
100-051-277
600
600
× 2P
325-12
YF-1
YET-300-1
TD-328
TD-315
TP-325
100-051-277
4A0300
250
× 2P
–
M12
150-L12
YF-1
YET-300-1
TD-325
TD-313
TP-150
100-051-562
300
× 2P
–
150-L12
YF-1
YET-300-1
TD-325
TD-313
TP-150
100-051-562
350
× 2P
–
200-L12
YF-1
YET-300-1
TD-327
TD-314
TP-200
100-051-564
400
× 2P
200-L12
YF-1
YET-300-1
TD-327
TD-314
TP-200
100-051-564
500
× 2P
325-12
YF-1
YET-300-1
TD-328
TD-315
TP-325
100-051-277
600
× 2P
325-12
YF-1
YET-300-1
TD-328
TD-315
TP-325
100-051-277
<1> Codes refer to a set of three crimp terminals and three insulation caps. Prepare input and output wiring using two sets for each connection.
Example 1: Model 4A0105 with 300 kcmil for both input and output require one set for input terminals and one set for output terminals, so the
user should order two sets of [100-051-272].
Example 2: Model 4A0210 with 300 kcmil
× 2P for both input and output require two sets for input terminals and two sets for output terminals,
so the user should order four sets of [100-051-562].
Model
Wire Gauge (AWG, kcmil)
Screw
Size
Crimp Terminal
Model Number
Tool
Insulation Cap
Model No.
Code
<1>
R/L1,S/L2,T/L3
,
Machine No.
Die Jaw
–
+
TOEP_C710656_08B_1_0.book 216 ページ 2015年2月5日 木曜日 午前10時7分