YASKAWA ELECTRIC TOEP C710656 08B YASKAWA Power Regenerative Unit - R1000 Instruction Manual

D.2 European Standards

D.2 European Standards

Figure D.1

Figure D.1 CE Mark

The CE mark indicates compliance with European safety and environmental regulations. It is required for engaging in
business and commerce in Europe.
European standards include the Machinery Directive for machine manufacturers, the Low Voltage Directive for
electronics manufacturers, and the EMC guidelines for controlling electrical noise.

This regenerative unit displays the CE mark based on the EMC guidelines and the Low Voltage Directive.

• Low Voltage Directive: 2006/95/EC
• EMC Guidelines: 2004/108/EC

Devices used in combination with this regenerative unit must also be CE certified and display the CE mark. When using
regenerative unit displaying the CE mark in combination with other devices, it is ultimately the responsibility of the user
to ensure compliance with CE standards. After setting up the device, verify that conditions meet European standards.

CE Low Voltage Directive Compliance

This regenerative unit has been tested according to European standard IEC 61800-5-1, and it fully complies with the Low
Voltage Directive.

To comply with the Low Voltage Directive, be sure to meet the following conditions when combining this regenerative
unit with other devices:

Area of Use

Do not use regenerative unit in areas with pollution higher than severity 2 and overvoltage category 3 in accordance with
IEC 664.

Standard Configuration Devices

Install appropriate standard configuration devices to the input side to protect regenerative unit wiring and prevent other
secondary damage. Select input fuses according to

Table D.1

.

Refer to

Power Ratings on page 148

for details on the regenerative unit Input Current and Rated Output Current.

NOTICE: If a fuse is open or a Ground Fault Circuit Interrupter (GFCI) is tripped, check the wiring and the selection of peripheral

devices to identify the cause. Contact Yaskawa before restarting the regenerative unit or the peripheral devices if the cause cannot be

identified.

Table D.1 Recommended Standard Configuration Devices

Model

Three Phase Input Fuse

Three Phase Input AC

Reactor (3%L)

Three Phase Input AC

Reactor (1%L)

Fuse

Holder

SHANGHAI EAGTOP

ELECTRONIC TECHNOLOGY

CO LTD

Sao Electric Corporation

Model

Ratings

Model

Ratings

Manufacturer

Model

Ratings

Model

Ratings

200 V Class

2…03P5 350GH-20ULTC 380 V, 20 A

HT4017

400 V, 75 A

HINODE

ACL-0020-EISC

-9353BBH

264 V, 20 A,

0.53 mH

300-057-271

264 V, 15 A,

0.31 mH

2…0005 350GH-25ULTC 380 V, 25 A

HT4017

400 V, 75 A

HINODE

ACL-0030-EISC

-9353BBH

264 V, 30 A,

0.35 mH

300-057-271

264 V, 15 A,

0.31 mH

2…0007 350GH-32ULTC 380 V, 32 A

HT4017

400 V, 75 A

HINODE

ACL-0040-EISC

-9353BBH

264 V, 40 A,

0.265 mH

300-057-272

264 V, 20 A,

0.15 mH