ers

Display step

MP7290.0 (X axis) to MP7290.13 (14th axis)
0.1 mm:

0

0.05 mm:

1

0.01 mm:

2

0.005 mm:

3

0.001 mm:

4

0.0005 mm:

5

0.0001 mm:

6

Disabling datum

setting in the preset

table

MP7294
Do not disable datum setting:

%00000000000000

Disable datum setting in the X axis:

Bit 0 = 1

Disable datum setting in the Y axis:

Bit 1 = 1

Disable datum setting in the Z axis:

Bit 2 = 1

Disable datum setting in the IVth axis:

Bit 3 = 1

Disable datum setting in the Vth axis:

Bit 4 = 1

Disable datum setting in the 6th axis:

Bit 5 = 1

Disable datum setting in the 7th axis:

Bit 6 = 1

Disable datum setting in the 8th axis:

Bit 7 = 1

Disable datum setting in the 9th axis:

Bit 8 = 1

Disable datum setting in the 10th axis:

Bit 9 = 1

Disable datum setting in the 11th axis:

Bit 10 = 1

Disable datum setting in the 12th axis:

Bit 11 = 1

Disable datum setting in the 13th axis:

Bit 12 = 1

Disable datum setting in the 14th axis:

Bit 13 = 1

Disabling datum

setting

MP7295
Do not disable datum setting:

%00000000000000

Disable datum setting in the X axis:

Bit 0 = 1

Disable datum setting in the Y axis:

Bit 1 = 1

Disable datum setting in the Z axis:

Bit 2 = 1

Disable datum setting in the IVth axis:

Bit 3 = 1

Disable datum setting in the Vth axis:

Bit 4 = 1

Disable datum setting in the 6th axis:

Bit 5 = 1

Disable datum setting in the 7th axis:

Bit 6 = 1

Disable datum setting in the 8th axis:

Bit 7 = 1

Disable datum setting in the 9th axis:

Bit 8 = 1

Disable datum setting in the 10th axis:

Bit 9 = 1

Disable datum setting in the 11th axis:

Bit 10 = 1

Disable datum setting in the 12th axis:

Bit 11 = 1

Disable datum setting in the 13th axis:

Bit 12 = 1

Disable datum setting in the 14th axis:

Bit 13 = 1

Disable datum setting

with the orange axis

keys

MP7296
Do not disable datum setting:

0

Disable datum setting with the orange axis keys:

1

TNC displays, TNC editor