Selecting touch probe cycles, 6 using to uc h-pr obes – HEIDENHAIN iTNC 530 (60642x-04) ISO programming User Manual
Page 509

HEIDENHAIN iTNC 530
509
14.6
Using
to
uc
h-pr
obes
Selecting touch probe cycles
Select the Manual Operation or El. Handwheel mode of operation
Select the touch probe functions: Press the TOUCH
PROBE soft key. The TNC displays additional soft 
keys: see table above
Select the touch probe cycle by pressing the
appropriate soft key, for example PROBING ROT for 
the TNC to display the associated menu
Recording measured values from the touch-
probe cycles
After executing any selected probe cycle, the TNC displays the soft 
key PRINT. If you press this soft key, the TNC will record the current 
values determined in the active touch probe cycle. You can then use 
the PRINT function in the menu for setting the data interface (see the 
User's Manual Chapter 12, "MOD Functions, Setting the Data 
Interfaces") to define whether the TNC is to
print the measuring result,
store the measuring results on the TNC’s hard disk, or
store the measuring results on a PC.
If you store the measuring results, the TNC creates the ASCII file 
%TCHPRNT.A. Unless you define a specific path and interface in the 
interface configuration menu, the TNC will store the %TCHPRNT file 
in the main directory TNC:\. 
The TNC must be specially prepared by the machine tool 
builder for use of this function. The machine manual 
provides further information.
When you press the PRINT soft key, the %TCHPRNT.A 
file must not be active in the Programming and Editing 
mode of operation. The TNC will otherwise display an error 
message.
The TNC stores the measured data in the %TCHPRNT.A 
file only. If you execute several touch probe cycles in 
succession and want to store the resulting measured data, 
you must make a backup of the contents stored in 
%TCHPRNT.A between the individual cycles by copying 
or renaming the file.
Format and contents of the %TCHPRNT file are preset by 
the machine tool builder. 