beautypg.com

HEIDENHAIN iTNC 530 (60642x-04) ISO programming User Manual

Page 391

background image

HEIDENHAIN iTNC 530

391

11

.5 Global Pr

ogr

am Set

tings (sof

tw

ar

e option)

Description of function

The functions for defining the limit plane are available in the Global
Program Settings form on the Limit plane tab. Once you enabled the
Limit Plane function (On/Off check box) and selected a check box to
activate an axis range, the TNC graphically displays this plane on the
right side of the screen. The green cuboid represents your machine's
traverse range.

Danger of collision!

Please note that the definition of one or more limit planes
will result in positioning movements that are not defined
in the NC program, and therefore cannot be simulated!

Use the Limit Plane function only in conjunction with
straight-line blocks. The TNC does not monitor any circular
movements!

For mid-program startup at a position outside the active
traverse range, the TNC positions the tool to the position
at which it would leave the defined traverse range.

If the tool is located at a position outside the traverse
range when a cycle is called, then the cycle will not be
executed!

The TNC executes all miscellaneous functions M that are
defined outside the traverse range in the NC program.
This also applies to PLC positioning movements or
traverse commands from NC macros.

The limit plane function is also active in MDI mode.