beautypg.com

18 .1 gener al user par amet ers – HEIDENHAIN iTNC 530 (60642x-04) ISO programming User Manual

Page 621

background image

HEIDENHAIN iTNC 530

621

18

.1

Gener

al

user

par

amet

ers

Radius measurement with the TT 130 touch

probe: Probing direction

MP6505.0 (traverse range 1) to 6505.2 (traverse range 3)
Positive probing direction in the angle reference axis (0° axis):

0

Positive probing direction in the +90° axis:

1

Negative probing direction in the angle reference axis (0° axis):

2

Negative probing direction in the +90° axis:

3

Probing feed rate for second measurement

with TT 130, stylus shape, corrections in

TOOL.T

MP6507
Calculate feed rate for second measurement with TT 130,
with constant tolerance:

Bit 0 = 0

Calculate feed rate for second measurement with TT 130,
with variable tolerance:

Bit 0 = 1

Constant feed rate for second measurement with TT 130:

Bit 1 = 1

Maximum permissible measuring error

with TT 130 during measurement with

rotating tool

Required for calculating the probing feed rate in
connection with MP6570

MP6510.0

0.001 to 0.999 [mm] (recommended input value: 0.005 mm)

MP6510.1

0.001 to 0.999 [mm] (recommended input value: 0.01 mm)

Feed rate for probing a stationary tool with

the TT 130

MP6520

1 to 3000 [mm/min]

Radius measurement with the TT 130:

Distance from lower edge of tool to upper

edge of stylus

MP6530.0 (traverse range 1) to MP6530.2 (traverse range 3)

0.001 to 99.9999 [mm]

Set-up clearance in the tool axis above the

stylus of the TT 130 for pre-positioning

MP6540.0

0.001 to 30 000.000 [mm]

Clearance zone in the machining plane

around the stylus of the TT 130 for pre-

positioning

MP6540.1

0.001 to 30 000.000 [mm]

Rapid traverse for TT 130 in the probe cycle

MP6550

10 to 10 000 [mm/min]

M function for spindle orientation during

individual tooth measurement

MP6560

0 to 999

-1: Function inactive

Measuring rotating tools: Permissible

rotational speed at the circumference of the

milling tool

Required for calculating rpm and probe feed
rate

MP6570

1.000 to 120.000 [m/min]

Measuring rotating tools: Permissible

rotational rpm

MP6572

0.000 to 1000.000 [rpm]
If you enter 0, the speed is limited to 1000 rpm

Touch probes