346

Programming: Miscellaneous Functions

10

.4

Miscellaneous

functions

fo

r

cont

our

ing

beha

vior

Restrictions

After an external or internal stop, you can only re-enter
the contour with the function RESTORE POS. AT N.
Before you start the block scan, you must cancel M120
(select program again via PGM MGT, do not use GOTO
0), otherwise the TNC will output an error message

When using the path functions G25 and G24, the blocks
before and after G25 or G24 must contain only
coordinates in the working plane.

If you enter an LA value that is too great, the edited
contour might change, because the TNC might then
output too many NC blocks

Before using the functions listed below, you have to
cancel M120 and the radius compensation:

Cycle G60 Tolerance

Cycle G80 Working plane

PLANE function

M114

M128

M138

M144

TCPM FUNCTION (only conversational format)