beautypg.com

9 w or kpiece pr eset ting with a to uc h pr obe – HEIDENHAIN iTNC 530 (60642x-04) ISO programming User Manual

Page 528

background image

528

Manual Operation and Setup

14.9

W

or

kpiece

pr

eset

ting

with

a

to

uc

h

pr

obe

Measuring workpiece dimensions

Select the probing function: Press the PROBING POS

soft key

Position the touch probe at a position near the first

touch point A

Select the probing direction by soft key

Start the probing procedure: Press the NC Start button

If you need the current datum later, write down the

value that appears in the Datum display

Datum: Enter "0"

Cancel the dialog: Press the END key

Select the probing function again: Press the PROBING

POS soft key

Position the touch probe at a position near the second

touch point B

Select the probe direction with the soft keys: Same

axis but from the opposite direction

Start the probing procedure: Press the NC Start button

The value displayed as preset is the distance between the two points
on the coordinate axis.

To return to the preset that was active before the length
measurement:

Select the probing function: Press the PROBING POS soft key

Probe the first touch point again

Set the datum to the value that you wrote down previously

Cancel the dialog: Press the END key

Angle measurement

You can use a touch probe to measure angles in the working plane.
You can measure

the angle between the angle reference axis and a workpiece edge,
or

the angle between two sides

The measured angle is displayed as a value of maximum 90°.

Y

X

Z

A

B

l