beautypg.com

List of general user parameters, 18 .1 gener al user par amet ers – HEIDENHAIN iTNC 530 (60642x-04) ISO programming User Manual

Page 619

background image

HEIDENHAIN iTNC 530

619

18

.1

Gener

al

user

par

amet

ers

List of general user parameters

External data transfer

Adjusting TNC interfaces EXT1 (5020.0) and

EXT2 (5020.1) to an external device

MP5020.x
7 data bits (ASCII code, 8th bit = parity):

Bit 0 = 0

8 data bits (ASCII code, 9th bit = parity):

Bit 0 = 1

Block Check Character (BCC) any:

Bit 1 = 0

Block Check Character (BCC) control character not permitted:

Bit 1 = 1

Transmission stop through RTS active:

Bit 2 = 1

Transmission stop through RTS inactive:

Bit 2 = 0

Transmission stop through DC3 active:

Bit 3 = 1

Transmission stop through DC3 inactive:

Bit 3 = 0

Character parity even:

Bit 4 = 0

Character parity odd:

Bit 4 = 1

Character parity undesired:

Bit 5 = 0

Character parity desired:

Bit 5 = 1

Number of stop bits that are transmitted at the end of a character:
1 stop bit:

Bit 6 = 0

2 stop bits:

Bit 6 = 1

1 stop bit:

Bit 7 = 1

1 stop bit:

Bit 7 = 0

Example:

Use the following setting to adjust the TNC interface EXT2 (MP 5020.1) to
an external non-HEIDENHAIN device:

8 data bits, any BCC, transmission stop through DC3, even character
parity, character parity desired, 2 stop bits

Input for

MP 5020.1: %01101001

Interface type for EXT1 (5030.0) and

EXT2 (5030.1)

MP5030.x
Standard transmission:

0

Interface for blockwise transfer:

1

Touch probes

Selecting signal transmission

MP6010
Touch probe with cable transmission:

0

Touch probe with infrared transmission:

1

Probing feed rate for triggering touch

probes

MP6120

1 to 3000 [mm/min]

Maximum traverse to first touch point

MP6130

0.001 to 99 999.9999 [mm]

Safety clearance to probing point during

automatic measurement

MP6140

0.001 to 99 999.9999 [mm]