619
18
.1
Gener
al
user
par
amet
ers
List of general user parameters
External data transfer
Adjusting TNC interfaces EXT1 (5020.0) and
EXT2 (5020.1) to an external device
MP5020.x
7 data bits (ASCII code, 8th bit = parity):
Bit 0 = 0
8 data bits (ASCII code, 9th bit = parity):
Bit 0 = 1
Block Check Character (BCC) any:
Bit 1 = 0
Block Check Character (BCC) control character not permitted:
Bit 1 = 1
Transmission stop through RTS active:
Bit 2 = 1
Transmission stop through RTS inactive:
Bit 2 = 0
Transmission stop through DC3 active:
Bit 3 = 1
Transmission stop through DC3 inactive:
Bit 3 = 0
Character parity even:
Bit 4 = 0
Character parity odd:
Bit 4 = 1
Character parity undesired:
Bit 5 = 0
Character parity desired:
Bit 5 = 1
Number of stop bits that are transmitted at the end of a character:
1 stop bit:
Bit 6 = 0
2 stop bits:
Bit 6 = 1
1 stop bit:
Bit 7 = 1
1 stop bit:
Bit 7 = 0
Example:
Use the following setting to adjust the TNC interface EXT2 (MP 5020.1) to
an external non-HEIDENHAIN device:
8 data bits, any BCC, transmission stop through DC3, even character
parity, character parity desired, 2 stop bits
Input for
MP 5020.1: %01101001
Interface type for EXT1 (5030.0) and
EXT2 (5030.1)
MP5030.x
Standard transmission:
0
Interface for blockwise transfer:
1
Touch probes
Selecting signal transmission
MP6010
Touch probe with cable transmission:
0
Touch probe with infrared transmission:
1
Probing feed rate for triggering touch
probes
MP6120
1 to 3000 [mm/min]
Maximum traverse to first touch point
MP6130
0.001 to 99 999.9999 [mm]
Safety clearance to probing point during
automatic measurement
MP6140
0.001 to 99 999.9999 [mm]