7 calibr ating touc h pr obes – HEIDENHAIN iTNC 530 (60642x-04) ISO programming User Manual
Page 514

514
Manual Operation and Setup
14.7
Calibr
ating
touc
h
pr
obes
Calibrating the effective radius and 
compensating center offset
After the touch probe is inserted, it normally needs to be aligned 
exactly with the spindle axis. The calibration function determines the 
misalignment between touch probe axis and spindle axis and 
computes the compensation.
The calibration routine varies depending on the setting of Machine 
Parameter 6165 (spindle orientation active/inactive). If the function for 
orienting the infrared touch probe to the programmed probe direction 
is active, the calibration cycle is executed after you have pressed NC 
Start once. If the function is not active, you can decide whether you 
want to compensate the center misalignment by calibrating the 
effective radius.
The TNC rotates the touch probe by 180° for calibrating the center 
misalignment. The rotation is initiated by a miscellaneous function that 
is set by the machine tool builder in Machine Parameter 6160.
Proceed as follows for manual calibration:
In the Manual Operation mode, position the ball tip inside the bore 
of the ring gauge
Select the calibration function for the ball-tip radius
and the touch probe center misalignment: Press the 
CAL. R soft key
Select the tool axis and enter the radius of the ring
gauge
Probing: press the NC Start button four times. The
touch probe contacts a position on the hole in each 
axis direction and calculates the effective ball-tip 
radius
If you want to terminate the calibration function at this
point, press the END soft key
If you want to determine the ball-tip center
misalignment, press the 180° soft key. The TNC 
rotates the touch probe by 180°
Probing: press the NC Start button four times. The
touch probe contacts a position in the hole in each 
axis direction and calculates the ball-tip center 
misalignment
Y
X
Z
10
In order to be able to determine the ball-tip center 
misalignment, the TNC needs to be specially prepared by 
the machine manufacturer. The machine manual provides 
further information.