1 gener a l user p a ra met e rs – HEIDENHAIN iTNC 530 (340 422) ISO programming User Manual
Page 515

HEIDENHAIN iTNC 530
515
13.1 Gener
a
l User P
a
ra
met
e
rs
Display step for the
spindle position
MP7289
0.1°: 0
0.05°: 1
0.01°: 2
0.005°: 3
0.001°: 4
0.0005°: 5
0.0001°: 6
Display step
MP7290.0 (X axis) to MP7290.8 (9th axis)
0.1 mm: 0
0.05 mm: 1
0.01 mm: 2
0.005 mm: 3
0.001 mm: 4
0.0005 mm: 5
0.0001 mm: 6
Disable datum setting
MP7295
Do not disable datum setting: +0
Disable datum setting in the X axis: +1
Disable datum setting in the Y axis: +2
Disable datum setting in the Z axis: +4
Disable datum setting in the IVth axis: +8
Disable datum setting in the Vth axis: +16
Disable datum setting in the 6th axis: +32
Disable datum setting in the 7th axis: +64
Disable datum setting in the 8th axis: +128
Disable datum setting in the 9th axis: +256
Disable datum setting
with the orange axis
keys
MP7296
Do not disable datum setting: 0
Disable datum setting with the orange axis keys: 1
Reset status display,
Q parameters and tool
data
MP7300
Reset all when a program is selected: 0
Reset all when a program is selected and with M02, M30, END PGM: 1
Reset only status display and tool data when a program is selected: 2
Reset only status display and tool data when a program is selected and with M02, M30,
END PGM: 3
Reset status display and Q parameters when a program is selected: 4
Reset status display and Q parameters when a program is selected and with M02, M30,
END PGM: 5
Reset status display when a program is selected: 6
Reset status display when a program is selected and with M02, M30, END PGM: 7
Graphic display mode
MP7310
Projection in three planes according to ISO 6433, projection method 1: +1
Projection in three planes according to ISO 6433, projection method 2: +1
Do not rotate coordinate for graphic display: +0
Rotate coordinate system for graphic display by 90°: +2
Display new BLK FORM in Cycle 7 DATUM SHIFT referenced to the old datum: +0
Display new BLK FORM in Cycle 7 DATUM SHIFT referenced to the new datum: +4
Do not show cursor position during projection in three planes: +0
Show cursor position during projection in three planes: +8