beautypg.com

12 pallet management, Function – HEIDENHAIN iTNC 530 (340 422) ISO programming User Manual

Page 119

background image

HEIDENHAIN iTNC 530

119

4.12 P

a

llet Manag

e

ment

4.12 Pallet Management

Function

Pallet tables are used for machining centers with pallet changers: The
pallet table calls the part programs that are required for the different
pallets, and activates datum shifts or datum tables.

You can also use pallet tables to run in succession several programs
that have different datums.

Pallet tables contain the following information:

n

PAL/PGM

(entry obligatory):

Identification for pallet or NC program (select with ENT or NO ENT)

n

NAME

(entry obligatory):

Pallet or program name. The machine tool builder determines the
pallet name (see Machine Manual). The program name must be
stored in the same directory as the pallet table. Otherwise you must
enter the full path name for the program.

n

DATUM

(entry optional):

Name of the datum table. The datum table must be stored in the
same directory as the pallet table. Otherwise you must enter the full
path name for the datum table. Datums from the datum table can be
activated in the NC program with Cycle G53 DATUM SHIFT.

n

X, Y, Z

(entry optional, other axes also possible):

For pallet names, the programmed coordinates are referenced to
the machine datum. For NC programs, the programmed coordinates
are referenced to the pallet datum. These entries overwrite the
datum that you last set in the Manual mode of operation. With the
miscellaneous function M104 you can reactivate the datum that was
last set. With the actual-position-capture key, the TNC opens a
window that enables you to have the TNC enter various points as
datums (see table below):

Pallet table management is a machine-dependent
function. The standard functional range will be described
below. Refer to your machine manual for more
information.

Position

Meaning

Actual values

Enter the coordinates of the current tool position
referenced to the active coordinate system.

Reference
values

Enter the coordinates of the current tool position
referenced to the machine datum.

ACTL

measured

values

Enter the coordinates referenced to the active
coordinate system of the datum last probed in
the Manual operating mode.

REF

measured

values

Enter the coordinates referenced to the machine
datum of the datum last probed in the Manual
operating mode.