1 gener a l user p a ra met e rs – HEIDENHAIN iTNC 530 (340 422) ISO programming User Manual
Page 508

508
13 Tables and Overviews
13.1 Gener
a
l User P
a
ra
met
e
rs
Measure center misalignment of the stylus
when calibrating a triggering touch probe
MP6160
No 180° rotation of the 3-D touch probe during calibration: 0
M function for 180° rotation of the touch probe during calibration: 1 to 999
M function for orienting the infrared sensor
before each measuring cycle
MP6161
Function inactive: 0
Orientation directly through the NC: -1
M function for orienting the touch probe: 1 to 999
Angle of orientation for the infrared sensor
MP6162
0 to 359.9999 [°]
Difference between the current angle of
orientation and the angle of orientation set
in MP 6162; when the entered difference is
reached, an oriented spindle stop is to be
carried out.
MP6163
0 to 3.0000 [°]
Automatically orient the infrared sensor
before probing to the programmed probing
direction
MP6165
Function inactive: 0
Orient infrared sensor: 1
Multiple measurement for programmable
probe function
MP6170
1 to 3
Confidence range for multiple
measurement
MP6171
0.001 to 0.999 [mm]
Automatic calibration cycle: Center of the
calibration ring in the X axis referenced to
the machine datum
MP6180.0 (traverse range 1) to MP6180.2 (traverse range3)
0 to 99 999.9999 [mm]
Automatic calibration cycle: Center of the
calibration ring in the Y axis referenced to
the machine datum
MP6181.0 (traverse range 1) to MP6181.2 (traverse range 3)
0 to 99 999.9999 [mm]
Automatic calibration cycle: Upper edge of
the calibration ring in the Z axis referenced
to the machine datum
MP6182.0 (traverse range 1) to MP6182.2 (traverse range 3)
0 to 99 999.9999 [mm]
Automatic calibration cycle: Distance below
the upper edge of the ring where the
calibration is carried out by the TNC
MP6185.0 (traverse range 1) to MP6185.2 (traverse range 3)
0.1 to 99 999.9999 [mm]
Radius measurement with the TT 130 touch
probe: Probing direction
MP6505.0 (traverse range 1) to 6505.2 (traverse range 3)
Positive probing direction in the angle reference axis (0° axis): 0
Positive probing direction in the +90° axis: 1
Negative probing direction in the angle reference axis (0° axis): 2
Negative probing direction in the +90° axis: 3
Probing feed rate for second measurement
with TT 120, stylus shape, corrections in
TOOL.T
MP6507
Calculate feed rate for second measurement with TT 130,
with constant tolerance: +0
Calculate feed rate for second measurement with TT 130,
with variable tolerance: +1
Constant feed rate for second measurement with TT 130: +2
3-D touch probes and digitizing