2 t o ol d a ta – HEIDENHAIN iTNC 530 (340 422) ISO programming User Manual
Page 140

140
5 Programming: Tools
5.2 T
o
ol D
a
ta
Tool table: Tool data required for automatic tool measurement
TIME2
Maximum tool life in minutes during a tool call: If the current tool
age exceeds this value, the TNC changes the tool during the next
tool call (see also CUR.TIME).
Maximum tool age for TOOL CALL?
CUR.TIME
Time in minutes the tool has been in use: The TNC automatically
counts the current tool age. A starting value can be entered for
used tools.
Current tool life?
DOC
Comment on tool (up to 16 characters)
Tool description?
PLC
Information on this tool that is to be sent to the PLC
PLC status?
PLC VAL
Value of this tool that is to be sent to the PLC
PLC value?
PTYP
Tool type for evaluation in the pocket table
Tool type for pocket table?
NMAX
Limits the spindle speed for this tool. The programmed value is
monitored (error message) as well as a shaft speed increase via
the potentiometer. Function inactive: Enter “–”
Maximum speed [rpm]?
Abbr.
Input
Dialog
For a description of the cycles governing automatic tool
measurement, see the Touch Probe Cycles Manual,
Chapter 4.
Abbr.
Input
Dialog
CUT
Number of teeth (20 teeth maximum)
Number of teeth?
LTOL
Permissible deviation from tool length L for wear detection. If the
entered value is exceeded, the TNC locks the tool (status L). Input
range: 0 to 0.9999 mm
Wear tolerance: length?
RTOL
Permissible deviation from tool radius R for wear detection. If the
entered value is exceeded, the TNC locks the tool (status L). Input
range: 0 to 0.9999 mm
Wear tolerance: radius?
DIRECT.
Cutting direction of the tool for measuring the tool during rotation
Cutting direction (M3 = –)?
TT:R-OFFS
For tool length measurement: tool offset between stylus center
and tool center. Preset value: Tool radius R (NO ENT means R).
Tool offset: radius?
TT:L-OFFS
Tool radius measurement: tool offset in addition to MP6530 (see
“General User Parameters” on page 506) between upper surface
of stylus and lower surface of tool. Default: 0
Tool offset: length?
LBREAK
Permissible deviation from tool length L for breakage detection. If
the entered value is exceeded, the TNC locks the tool (status L).
Input range: 0 to 0.9999 mm
Breakage tolerance: length?
RBREAK
Permissible deviation from tool radius R for breakage detection. If
the entered value is exceeded, the TNC locks the tool (status L).
Input range: 0 to 0.9999 mm
Breakage tolerance: radius?