Table for tool cutting materials, Table for cutting data, 5 w o rk in g wi th cut ting d a ta t a ble s – HEIDENHAIN iTNC 530 (340 422) ISO programming User Manual
Page 157

HEIDENHAIN iTNC 530
157
5.5 W
o
rk
in
g wi
th
Cut
ting D
a
ta T
a
ble
s
Table for tool cutting materials
Tool cutting materials are defined in the TMAT.TAB table. TMAT.TAB
is stored in the TNC:\ directory and can contain as many material
names as you want (see figure at upper right). The name of the cutting
material type can have up to 16 characters (including spaces). The TNC
displays the NAME column when you are defining the tool cutting
material in the TOOL.T tool table.
Table for cutting data
Define the workpiece material / cutting material combinations with the
corresponding cutting data in a file table with the file name extension
.CDT; see figure at center right. You can freely configure the entries
in the cutting data table. Besides the obligatory columns NR, WMAT
and TMAT, the TNC can also manage up to four cutting speed (V
C
) /
feed rate (F) combinations.
The standard cutting data table FRAES_2.CDT is stored in the
directory TNC:\. You can edit FRAES_2.CDT, or add as many new
cutting-data tables as you wish.
If you change the standard tool cutting material table, you
must copy it into a new directory. Otherwise your
changes will be overwritten during a software update by
the HEIDENHAIN standard data. Define the path in the
TNC.SYS file with the code word TMAT= (see
“Configuration file TNC.SYS,” page 161).
To avoid losing data, save the TMAT.TAB file at regular
intervals.
If you change the standard cutting data table, you must
copy it into a new directory. Otherwise your changes will
be overwritten during a software update by the
HEIDENHAIN standard data (see “Configuration file
TNC.SYS,” page 161).
All of the cutting data tables must be stored in the same
directory. If the directory is not the standard directory
TNC:\, then behind the code word PCDT= you must enter
the path in which your cutting data is stored.
To avoid losing data, save your cutting data tables at
regular intervals.