10 Programming: Q Parameters

1

0

.7 A

d

d

ition

al

F

u

nc

tion

s

D15: PRINT: Output of texts or
Q parameter values

The function D15: PRINT transfers Q parameter values and error
messages through the data interface, for example to a printer. When
you save the data in the TNC memory or transfer them to a PC, the
TNC stores the data in the file %FN 15RUN.A (output in program run
mode) or in the file %FN15SIM.A (output in test run mode). The data
are transmitted from a buffer. Data output begins at the latest by
program end or when you stop the program. In the Single Block mode
of operation, data transfer begins at block end.

Output dialog texts and error messages with D15: PRINT
”numerical value”

Example: Output of dialog text 20

Output dialog texts and error messages with D15: PRINT
“Q parameter”

Application example: Recording workpiece measurement.

You can transfer up to six Q parameters and numerical values
simultaneously.

Example: Output of dialog text 1 and numerical value for Q1

D19: PLC: Transferring values to the PLC

The function D19: PLC transfers up to two numerical values or Q
parameter contents to the PLC.

Increments and units: 0.1 µm or 0.0001°

Example: Transfer the numerical value 10 (which means 1 µm or
0.001°) to the PLC

Setting the data interface: In the menu option PRINT or
PRINT-TEST, you must enter the path for storing the texts
or Q parameters (see “Assign,” page 479).

Numerical values from 0 to 99:

Dialog texts for OEM cycles

Numerical values exceeding 100: PLC Error Messages

N67 D15 P01 20 *

N70 D15 P01 1 P02 Q1 *

N56 D19 P01 +10 P02 +Q3 *