beautypg.com

Troubleshooting dldp, Symptom, Analysis – H3C Technologies H3C S7500E Series Switches User Manual

Page 71: Solution

background image

6-21

[DeviceA-GigabitEthernet2/0/1]

%Jan 18 18:22:46:065 2010 DeviceA IFNET/3/LINK_UPDOWN: GigabitEthernet2/0/1 link status is

UP.

The output above indicates that the link status of both GigabitEthernet 2/0/1 and GigabitEthernet 2/0/2

is now up.

Troubleshooting DLDP

Symptom

Two DLDP-enabled devices, Device A and Device B, are connected through two fiber pairs, in which

two fibers are cross-connected. The unidirectional links cannot be detected; all the four ports involved

are in Advertisement state.

Analysis

The problem can be caused by the following.

z

The intervals to send Advertisement packets on Device A and Device B are not the same.

z

DLDP authentication modes/passwords on Device A and Device B are not the same.

Solution

Make sure the interval to send Advertisement packets, the authentication mode, and the password

configured on Device A and Device B are the same.