z

On different devices, the MEPs belonging to the same MD and MA should be configured with the

same CCM sending interval.

z

If the device has multiple cards with assistant CPUs, the CCMs will be sent by one of these cards.

If the card that sends the CCMs is unplugged, another card will take over to send CCMs and CC

will be re-performed. If all the cards with assistant CPUs are unplugged, MEPs with the interval

field value set as 3 will stop sending CCMs immediately, while those with the interval field value

set as 4 to 7 will send CCMs through their host cards and CC over these MEPs will be

re-performed.

The relationship between the interval field value in the CCM messages, the interval between CCM

messages and the timeout time of the remote MEP is illustrated in

Table 5-1

.

Table 5-1 Relationship of the interval field value, the interval between CCM messages and the timeout

time of the remote MEP

The interval field value

The interval between CCM

messages

The timeout time of the remote

MEP

3

100 milliseconds

350 milliseconds

4

1 second

3.5 seconds

5

10 second

35 seconds

6

60 seconds

210 seconds

7

600 seconds

2100 seconds

In a non-IRF environment with EB or SD cards, the valid value range for the interval field is 3 to 7,

while in other cases, the valid value range for the interval field is 4 to 7.

Configuring LB on MEPs

The LB function can verify the link state between two ends after CC detects a link fault.

Follow these steps to configure LB on a MEP:

To do...