Configuring lb on meps – H3C Technologies H3C S7500E Series Switches User Manual
Page 45
5-10
z
On different devices, the MEPs belonging to the same MD and MA should be configured with the
same CCM sending interval.
z
If the device has multiple cards with assistant CPUs, the CCMs will be sent by one of these cards.
If the card that sends the CCMs is unplugged, another card will take over to send CCMs and CC
will be re-performed. If all the cards with assistant CPUs are unplugged, MEPs with the interval
field value set as 3 will stop sending CCMs immediately, while those with the interval field value
set as 4 to 7 will send CCMs through their host cards and CC over these MEPs will be
re-performed.
The relationship between the interval field value in the CCM messages, the interval between CCM
messages and the timeout time of the remote MEP is illustrated in
.
Table 5-1 Relationship of the interval field value, the interval between CCM messages and the timeout
time of the remote MEP
The interval field value
The interval between CCM
messages
The timeout time of the remote
MEP
3
100 milliseconds
350 milliseconds
4
1 second
3.5 seconds
5
10 second
35 seconds
6
60 seconds
210 seconds
7
600 seconds
2100 seconds
In a non-IRF environment with EB or SD cards, the valid value range for the interval field is 3 to 7,
while in other cases, the valid value range for the interval field is 4 to 7.
Configuring LB on MEPs
The LB function can verify the link state between two ends after CC detects a link fault.
Follow these steps to configure LB on a MEP:
To do...
Use the command...
Remarks
Enter system view
system-view
—