Master IP : FE80::1

VRRP Track Information:

Track Interface: Vlan3 State : Up Pri Reduced : 30

# Display the detailed information of VRRP group 1 on Switch B.

[SwitchB-Vlan-interface2] display vrrp ipv6 verbose

IPv6 Standby Information:

Run Mode : Standard

Run Method : Virtual MAC

Total number of virtual routers : 1

Interface Vlan-interface2

VRID : 1 Adver Timer : 400

Admin Status : Up State : Backup

Config Pri : 100 Running Pri : 100

Preempt Mode : Yes Delay Time : 5

Auth Type : Simple Key : hello

Virtual IP : FE80::10

1::10

Master IP : FE80::1

The above information shows that in VRRP group 1 Switch A is the master, Switch B is the

backup and packets sent from Host A to Host B are forwarded by Switch A.

When interface VLAN-interface 3 on Switch A is not available, you can still ping Host B

successfully on Host A. To view the detailed information of the VRRP group, use the display

vrrp ipv6 verbose command.

# When interface VLAN-interface 3 on Switch A is not available, the detailed information of

VRRP group 1 on Switch A is displayed.

[SwitchA-Vlan-interface2] display vrrp ipv6 verbose

IPv6 Standby Information:

Run Mode : Standard

Run Method : Virtual MAC

Total number of virtual routers : 1

Interface Vlan-interface2

VRID : 1 Adver Timer : 400

Admin Status : Up State : Backup

Config Pri : 110 Running Pri : 80

Preempt Mode : Yes Delay Time : 5

Auth Type : Simple Key : hello

Virtual IP : FE80::10

1::10

Master IP : FE80::2

VRRP Track Information:

Track Interface: Vlan3 State : Down Pri Reduced : 30

# When interface VLAN-interface 3 on Switch A is not available, the detailed information of

VRRP group 1 on Switch B is displayed.

[SwitchB-Vlan-interface2] display vrrp ipv6 verbose

IPv6 Standby Information:

Run Mode : Standard

Run Method : Virtual MAC

Total number of virtual routers : 1

Interface Vlan-interface2

This manual is related to the following products: