Figure 12-5 Network diagram for static routing-track-NQA collaboration configuration

Vlan-int5
10.2.1.2/24

Vlan-int2

10.1.1.2/24

Vlan-int2
10.1.1.1/24

Switch B

Switch A

Switch C

Vlan-int3

10.3.1.1/24

Vlan-int3

10.3.1.3/24

Vlan-int4
10.4.1.3/24

Switch D

Vlan-int5

10.2.1.4/24

Vlan-int4
10.4.1.4/24

30.1.1.0/24

20.1.1.0/24

Vlan-int6

20.1.1.1/24

Vlan-int7
30.1.1.1/24

Configuration procedure

1) Create VLANs, and assign corresponding ports to the VLANs, and configure the IP address of

each VLAN interface as shown in Figure 12-5. The configuration procedure is omitted.

2) Configure Switch A

# Configure a static route to 30.1.1.0/24, with the address of the next hop as 10.1.1.2 and the default

priority 60. This static route is associated with track entry 1.

system-view

[SwitchA] ip route-static 30.1.1.0 24 10.1.1.2 track 1

# Configure a static route to 30.1.1.0/24, with the address of the next hop as 10.3.1.3 and the priority

80.

[SwitchA] ip route-static 30.1.1.0 24 10.3.1.3 preference 80

# Configure a static route to 10.2.1.4, with the address of the next hop as 10.1.1.2.

[SwitchA] ip route-static 10.2.1.4 24 10.1.1.2

# Create an NQA test group with the administrator admin and the operation tag test.

[SwitchA] nqa entry admin test

# Configure the test type as ICMP-echo.

[SwitchA-nqa-admin-test] type icmp-echo

# Configure the destination address of the test as 10.2.1.4 and the next hop address as 10.1.1.2 to

check the connectivity of the path from Switch A to Switch B, and then to Switch D through NQA.

[SwitchA-nqa-admin-test-icmp-echo] destination ip 10.2.1.4

[SwitchA-nqa-admin-test-icmp-echo] next-hop 10.1.1.2

# Configure the test frequency as 100 ms.

[SwitchA-nqa-admin-test-icmp-echo] frequency 100

# Configure reaction entry 1, specifying that five consecutive probe failures trigger the Static

Routing-Track-NQA collaboration.

[SwitchA-nqa-admin-test-icmp-echo] reaction 1 checked-element probe-fail threshold-type

consecutive 5 action-type trigger-only

[SwitchA-nqa-admin-test-icmp-echo] quit

# Start NQA probes.