Configuration procedure – H3C Technologies H3C S7500E Series Switches User Manual
Page 199
12-18
Figure 12-5 Network diagram for static routing-track-NQA collaboration configuration
Vlan-int5
10.2.1.2/24
Vlan-int2
10.1.1.2/24
Vlan-int2
10.1.1.1/24
Switch B
Switch A
Switch C
Vlan-int3
10.3.1.1/24
Vlan-int3
10.3.1.3/24
Vlan-int4
10.4.1.3/24
Switch D
Vlan-int5
10.2.1.4/24
Vlan-int4
10.4.1.4/24
30.1.1.0/24
20.1.1.0/24
Vlan-int6
20.1.1.1/24
Vlan-int7
30.1.1.1/24
Configuration procedure
1) Create VLANs, and assign corresponding ports to the VLANs, and configure the IP address of
each VLAN interface as shown in Figure 12-5. The configuration procedure is omitted.
2) Configure Switch A
# Configure a static route to 30.1.1.0/24, with the address of the next hop as 10.1.1.2 and the default
priority 60. This static route is associated with track entry 1.
[SwitchA] ip route-static 30.1.1.0 24 10.1.1.2 track 1
# Configure a static route to 30.1.1.0/24, with the address of the next hop as 10.3.1.3 and the priority
80.
[SwitchA] ip route-static 30.1.1.0 24 10.3.1.3 preference 80
# Configure a static route to 10.2.1.4, with the address of the next hop as 10.1.1.2.
[SwitchA] ip route-static 10.2.1.4 24 10.1.1.2
# Create an NQA test group with the administrator admin and the operation tag test.
[SwitchA] nqa entry admin test
# Configure the test type as ICMP-echo.
[SwitchA-nqa-admin-test] type icmp-echo
# Configure the destination address of the test as 10.2.1.4 and the next hop address as 10.1.1.2 to
check the connectivity of the path from Switch A to Switch B, and then to Switch D through NQA.
[SwitchA-nqa-admin-test-icmp-echo] destination ip 10.2.1.4
[SwitchA-nqa-admin-test-icmp-echo] next-hop 10.1.1.2
# Configure the test frequency as 100 ms.
[SwitchA-nqa-admin-test-icmp-echo] frequency 100
# Configure reaction entry 1, specifying that five consecutive probe failures trigger the Static
Routing-Track-NQA collaboration.
[SwitchA-nqa-admin-test-icmp-echo] reaction 1 checked-element probe-fail threshold-type
consecutive 5 action-type trigger-only
[SwitchA-nqa-admin-test-icmp-echo] quit
# Start NQA probes.