beautypg.com

Network requirements, Configuration procedure – H3C Technologies H3C S7500E Series Switches User Manual

Page 192

background image

12-11

Preempt Mode : Yes Delay Time : 5

Auth Type : Simple Key : hello

Virtual IP : 10.1.1.10

Virtual MAC : 0000-5e00-0101

Master IP : 10.1.1.2

The output information indicates that when there is a fault on the link between Switch A and Switch C,

the priority of Switch A decreases to 80. Switch A becomes the backup, and Switch B becomes the

master. Packets from Host A to Host B are forwarded through Switch B.

Configuring BFD for a VRRP Backup to Monitor the Master

Network requirements

z

As shown in

Figure 12-3

, Switch A and Switch B belong to VRRP group 1, the virtual IP address

of which is 192.168.0.10.

z

The default gateway of the hosts in the LAN is 192.168.0.10. When Switch A works normally, the

hosts in the LAN access the external network through Switch A. When Switch A fails, the hosts in

the LAN access the external network through Switch B.

z

If BFD is not configured, when the master in a VRRP group fails, the backup cannot become the

master until the configured timeout timer expires. The timeout is generally three to four seconds

and therefore the switchover is slow. To solve this problem, VRRP uses BFD to probe the state of

the master. Once the master fails, the backup can become the new master within 1 second.

Figure 12-3 Network diagram for monitoring the master on the backup

Internet

Virtual router

Virtual IP address:

192.168.0.10

Vlan-int2

192.168.0.101/24

Vlan-int2
192.168.0.102/24

Switch A

Master

Switch B

Backup

L2 switch

VRRP packets

BFD probe packets

Configuration procedure

1) Create VLANs, and assign corresponding ports to the VLANs, and configure the IP address of

each VLAN interface as shown in Figure 12-3. The configuration procedure is omitted.

This manual is related to the following products: