beautypg.com

Configuring extended oam, Enabling extended oam, Configuring extended oam discovery timeout time – H3C Technologies H3C S7500E Series Switches User Manual

Page 34

background image

4-3

The OLT can configure the following functions for the ONU:

z

Basic port configurations, including duplex mode, rate, and traffic control.

z

VLAN management and configuration

z

Multicast

z

QoS

z

DBA

The OLT can query and configure the functions mentioned above. You can use the related query

commands to query the status of a function on the ONU. You can also configure parameters for a

function on the OLT, and the OLT will issue the configured parameters to the ONU automatically. The

query or configuration command is identified by the Ext.Opcode field in the Organization Specific

OAMPDUs. The codes and configurations to be queried or configured are encapsulated in the payload

field. For details, refer to

Organization Specific OAMPDU

.

Configuring Extended OAM

Enabling Extended OAM

On an S7500E switch, you need not enable extend OAM manually; instead, extended OAM is enabled

on a port automatically when you enable Ethernet OAM on the port.

Configuring Extended OAM Discovery Timeout Time

Extended OAM discovery timeout time refers to the timeout time of extended OAM messages

exchanged between an OLT and its ONU during an extended OAM discovery process.

Follow these steps to configure the extended OAM discovery timeout time:

To do…

Use the command…

Remarks

Enter system view

system-view

Enter FTTH view

ftth

Configure the extended OAM

discovery timeout time

oam-discovery-timeout value

slot slot-number

Optional

The unit of measure for this

parameter is 100 ms. The default

value of this parameter is 30, that

is, 3 seconds.

z

You are recommended to use the default value of this parameter.

z

If an OLT stays down after being bundled with an ONU port, you can change the extended OAM

discovery timeout time to a larger value.

This manual is related to the following products: