Configuring extended oam, Enabling extended oam, Configuring extended oam discovery timeout time – H3C Technologies H3C S7500E Series Switches User Manual
Page 34
4-3
The OLT can configure the following functions for the ONU:
z
Basic port configurations, including duplex mode, rate, and traffic control.
z
VLAN management and configuration
z
Multicast
z
QoS
z
DBA
The OLT can query and configure the functions mentioned above. You can use the related query
commands to query the status of a function on the ONU. You can also configure parameters for a
function on the OLT, and the OLT will issue the configured parameters to the ONU automatically. The
query or configuration command is identified by the Ext.Opcode field in the Organization Specific
OAMPDUs. The codes and configurations to be queried or configured are encapsulated in the payload
field. For details, refer to
Configuring Extended OAM
Enabling Extended OAM
On an S7500E switch, you need not enable extend OAM manually; instead, extended OAM is enabled
on a port automatically when you enable Ethernet OAM on the port.
Configuring Extended OAM Discovery Timeout Time
Extended OAM discovery timeout time refers to the timeout time of extended OAM messages
exchanged between an OLT and its ONU during an extended OAM discovery process.
Follow these steps to configure the extended OAM discovery timeout time:
To do…
Use the command…
Remarks
Enter system view
system-view
—
Enter FTTH view
ftth
—
Configure the extended OAM
discovery timeout time
oam-discovery-timeout value
slot slot-number
Optional
The unit of measure for this
parameter is 100 ms. The default
value of this parameter is 30, that
is, 3 seconds.
z
You are recommended to use the default value of this parameter.
z
If an OLT stays down after being bundled with an ONU port, you can change the extended OAM
discovery timeout time to a larger value.