Enabling trap, Displaying and maintaining bfd – H3C Technologies H3C S7500E Series Switches User Manual

Page 180

background image

11-8

In

Figure 11-1

for example, if you configure the Desired Min TX Interval as 100 milleseconds,

Required Min Rx Interval as 300 milliseconds, and Detect Mult as 5 on Router A, and configure

the Desired Min TX Interval as 150 milleseconds, Required Min Rx Interval as 400 milliseconds,

and Detect Mult as 10 on Router B,

z

The actual transmitting interval on Router A is 300 milleseconds, that is, the greater value

between the minimum interval for transmitting BFD control packets on Router A and the

minimum interval for receiving BFD control packets on Router B.

z

The actual transmitting interval on Router B is 300 milleseconds, that is, the greater value

between the minimum interval for transmitting BFD control packets on Router B and the

minimum interval for receiving BFD control packets on Router A.

z

The actual detection time on Router A is 3000 milliseconds, that is, 10 × 300 milliseconds.

z

The actual detection time on Router B is 2000 milliseconds, that is, 5 × 400 milleseconds.

Enabling Trap

When the trap function is enabled on the BFD module, the module will generate trap messages

at the notifications level to report the important events of the module. The generated trap

messages are sent to the device's information center, which determines the output rules for the

trap messages, namely, whether to output the trap messages and the output destinations).

Follow these steps to enable BFD trap:

To do…

Use the command…

Remarks

Enter system view

system-view

Enable BFD trap

snmp-agent trap enable bfd

Optional

Enabled by default

z

For the description of the snmp-agent trap enable bfd command, see the snmp-agent

trap enable command in SNMP Configuration Commands in the Network Management and

Monitoring Command Reference.

z

For the information center configuration, see Information Center Configuration in the

Network Management and Monitoring Configuration Guide.

Displaying and Maintaining BFD

To do…

Use the command…

Remarks

Display information about BFD-enabled

interfaces

display bfd interface [ verbose ]

Available in any

view