beautypg.com

How ethernet oam works, Ethernet oam connection establishment – H3C Technologies H3C S7500E Series Switches User Manual

Page 22

background image

3-3

Table 3-2 Functions of different types of OAMPDUs

OAMPDU type

Function

Information OAMPDU

Used for transmitting state information of an Ethernet OAM entity (including

the information about the local device and remote devices, and customized

information) to the remote Ethernet OAM entity and maintaining OAM

connections

Event Notification OAMPDU

Used by link monitoring to notify the remote OAM entity when it detects

problems on the link in between.

Loopback Control OAMPDU

Used for remote loopback control. By inserting the information used to

enable/disable loopback to a loopback control OAMPDU, you can

enable/disable loopback on a remote OAM entity.

How Ethernet OAM Works

This section describes the working procedures of Ethernet OAM.

Ethernet OAM connection establishment

Ethernet OAM connection is the base of all the other Ethernet OAM functions. OAM connection

establishment is also known as the Discovery phase, where an Ethernet OAM entity discovers remote

OAM entities and establishes sessions with them.

In this phase, interconnected OAM entities notify the peer of their OAM configuration information and

the OAM capabilities of the local nodes by exchanging Information OAMPDUs and determine whether

Ethernet OAM connections can be established. An Ethernet OAM connection can be established only

when the settings concerning loopback, link detecting, and link event of the both sides match. After an

Ethernet OAM connection is established, Ethernet OAM takes effect on it.

As for Ethernet OAM connection establishment, a device can operate in active Ethernet OAM mode or

passive Ethernet OAM mode.

Table 3-3

compares active Ethernet OAM mode with passive Ethernet

OAM mode.

Table 3-3 Active Ethernet OAM mode and passive Ethernet OAM mode

Item

Active Ethernet OAM mode

Passive Ethernet OAM mode

Initiating OAM Discovery

Available

Unavailable

Responding to OAM Discovery

Available

Available

Transmitting Information

OAMPDUs

Available Available

Transmitting Event Notification

OAMPDUs

Available Available

Transmitting Information

OAMPDUs with the Data/Pad field

being empty

Available Available