Configuring lt on meps, Displaying and maintaining cfd – H3C Technologies H3C S7500E Series Switches User Manual

Page 46

background image

5-11

To do...

Use the command...

Remarks

Enable LB

cfd loopback service-instance

instance-id mep mep-id

{ target-mep target-mep-id |

target-mac mac-address }

[ number number ]

Required

Disabled by default

Configuring LT on MEPs

LT can trace the path between the specified MEP and the target MEP, and can also locate link faults by

sending LT messages automatically. The two functions are implemented in the following way:

z

To implement the first function, the specified MEP first sends LTM messages to the target MEP.

Based on the LTR messages in response to the LTM messages, the path between the two MEPs

can be identified.

z

In the latter case, after LT messages automatic sending is enabled, if a MEP fails to receive the

CCMs from the remote MEP within 3.5 sending intervals, the link between the two is considered

faulty and LTMs (with the remote MEP as the destination and the TTL field in the LTMs set to the

maximum value 255) will be sent out. Based on the LTRs that echo back, the fault source can be

located.

Follow these steps to configure LT on MEPs:

To do...

Use the command...

Remarks

Enter system view

system-view

Find the path between a source

MEP and a target MEP

cfd linktrace service-instance

instance-id mep mep-id

{ target-mep target-mep-id |

target-mac mac-address } [ ttl

ttl-value ] [ hw-only ]

Required

Enable LT messages automatic

sending

cfd linktrace auto-detection

[ size size-value ]

Required

Disabled by default.

Displaying and Maintaining CFD

To do...

Use the command...

Remarks

Display CFD status

display cfd status

Available in any view

Display the CFD protocol version

display cfd version

Available in any view

Display MD configuration

information

display cfd md

Available in any view