beautypg.com

Verifying the configuration – H3C Technologies H3C S12500-X Series Switches User Manual

Page 184

background image

174

system-view

[SwitchA] ipv6 multicast routing

[SwitchA-mrib6] quit

# Enable MLD on VLAN-interface 100 (the interface that connects to the stub network).

[SwitchA] interface vlan-interface 100

[SwitchA-Vlan-interface100] mld enable

[SwitchA-Vlan-interface100] quit

# Enable IPv6 PIM-DM on VLAN-interface 103.

[SwitchA] interface vlan-interface 103

[SwitchA-Vlan-interface103] ipv6 pim dm

[SwitchA-Vlan-interface103] quit

# Enable IPv6 multicast routing, MLD, and IPv6 PIM-DM on Switch B and Switch C in the same way
Switch A is configured. (Details not shown.)
# On Switch D, enable IPv6 multicast routing, and enable IPv6 PIM-DM on each interface.

system-view

[SwitchD] ipv6 multicast routing

[SwitchD-mrib6] quit

[SwitchD] interface vlan-interface 300

[SwitchD-Vlan-interface300] ipv6 pim dm

[SwitchD-Vlan-interface300] quit

[SwitchD] interface vlan-interface 103

[SwitchD-Vlan-interface103] ipv6 pim dm

[SwitchD-Vlan-interface103] quit

[SwitchD] interface vlan-interface 101

[SwitchD-Vlan-interface101] ipv6 pim dm

[SwitchD-Vlan-interface101] quit

[SwitchD] interface vlan-interface 102

[SwitchD-Vlan-interface102] ipv6 pim dm

[SwitchD-Vlan-interface102] quit

Verifying the configuration

# Display IPv6 PIM information on Switch D.

[SwitchD] display ipv6 pim interface

Interface NbrCnt HelloInt DR-Pri DR-Address

Vlan300 0 30 1 FE80::A01:201:1

(local)

Vlan103 0 30 1 FE80::A01:201:2

(local)

Vlan101 1 30 1 FE80::A01:201:3

(local)

Vlan102 1 30 1 FE80::A01:201:4

(local)

# Display IPv6 PIM neighboring relationship on Switch D.

[SwitchD] display ipv6 pim neighbor

Total Number of Neighbors = 3

Neighbor Interface Uptime Expires Dr-Priority