Solution
1.
Use the display acl ipv6 command to verify that the configured IPv6 ACL meets the IPv6 multicast
group filter requirements.
2.
Use the display this command in MLD-snooping view or in a corresponding interface view to verify
that the correct IPv6 multicast group filter has been applied. If not, use the group-policy or
mld-snooping group-policy command to apply the correct IPv6 multicast group filter.
3.
Use the display mld-snooping command to verify that the function of dropping unknown IPv6
multicast data is enabled. If not, use the drop-unknown or mld-snooping drop-unknown command
to enable dropping unknown IPv6 multicast data.
This manual is related to the following products:
- H3C S9800 Series Switches H3C S5560 Series Switches H3C S5130 Series Switches H3C S5120 Series Switches H3C S12500 Series Switches H3C SR8800 H3C SR6600-X H3C SR6600 H3C WX6000 Series Access Controllers H3C WX5000 Series Access Controllers H3C WX3000 Series Unified Switches H3C LSWM1WCM10 Access Controller Module H3C LSWM1WCM20 Access Controller Module H3C LSQM1WCMB0 Access Controller Module H3C LSRM1WCM2A1 Access Controller Module H3C LSBM1WCM2A0 Access Controller Module