5.5.4 LIU Status Indication
Synopsis:
Message issued by the board to notify of changes of LIU status.
Message Format:
MESSAGE HEADER
FIELD NAME
MEANING
type MVD_MSG_LIU_STATUS
(0x0e01)
id liu_id
src MVD_TASK_ID
dst MGMT_TASK_ID
rsp_req
0
hclass
0
status liu_status
(see below)
err_info
Reserved for future use
len
0
Description:
This message is issued by the board for every change of state on the trunk
interface.
Parameter Description:
liu_id:
The identity of the Line Interface Unit to which the status indication applies.
liu_status The status field in the message header is coded as follows:
Value Mnemonic
State
10 LIUS_SYNC_LOSS
Frame Sync Loss
11 LIUS_IN_SYNC
Frame Sync OK
12 LIUS_AIS
AIS Detected
13 LIUS_AIS_CLRD
AIS Cleared
14 LIUS_REM_ALARM
Remote Alarm
15 LIUS_REM_ALM_CLRD Remote Alarm Cleared
20 LIUS_PCM_LOSS
PCM Loss
21 LIUS_PCM_OK
PCM Restored
22 LIUS_FRAME_SLIP
Frame Slip
25 LIUS_BER5_OCRD
BER > 1 in 100,000
26 LIUS_BER5_CLRD
BER5 cleared
27 LIUS_BER3_OCRD
BER > 1 in 1,000
28 LIUS_BER3_CLRD
BER3 cleared