beautypg.com

Welltech SPCI2S Intel NetStructure SS7 Boards User Manual

Page 62

background image

SS7 Programmer’s Manual for SPCI2, SPCI4 and CPM8 Issue 2

Page 62

5.3.8 Fixed Data Output Request

Synopsis:


Message sent to the board in order to generate a fixed pattern on a specific E1
/ T1 Line Interface Unit timeslot.

Message Format:

MESSAGE HEADER

FIELD NAME

MEANING

type MVD_MSG_SC_FIXDATA (0x7e15)
id

0

src

Sending Module ID

dst MVD_TASK_ID (0x10)
rsp_req

Used to request a confirmation

hclass

0

status

0

err_info

0

len

6

PARAMETER AREA

OFFSET SIZE

NAME

0 2 liu_id
2 2 timeslot
4 2 pattern

Description:


This message is sent to the board in order to generate a fixed pattern on a
specific timeslot of an E1 / T1 Line Interface Unit. It is typically issued at
initialisation and whenever a call terminates to generate an IDLE pattern
towards the network.

Parameter Description:

liu_id


The identifier of the E1/T1 Line Interface Unit in the range 0 to one less than
the number of LIUs fitted.

timeslot


The timeslot number on the E1/T1 line interface unit on which the fixed data will
be transmitted. The valid range for timeslot is 1 to 31 for an E1 interface and 1
to 24 for a T1 interface.