Parameter Description:

board_type


The type of board to be reset. This should be set to 2 for SPCI2S, SPCI4 and
CPM8 boards.

phy_id


The physical id for the board. This field should be set to the same value as the
board_id. (ie 0 .. one less than the number of boards supported).

code_file


Null terminated string giving the filename of the code file to be downloaded to
the board.

run_mode


Number taken from the following table to indicate which protocols are to be run:

NOTE: It is only possible to activate protocols that have been licensed to run on
the board by use of a suitable licence button.

run_mode

Mnemonic

Protocols selected to run on the board

1

DTI

Digital Trunk Interface only, no protocol software. This mode does
NOT require the use of a software licence button).

2

MTP2

MTP2 protocol only.

3

MTP

MTP3 plus MTP2 protocols.

4

ISUP

ISUP, standard version, up to 256 circuits plus all MTP.

5

ISUP-L

ISUP, large version, up to 4096 circuits plus all MTP.

6

TUP

TUP, standard version, up to 256 circuits plus all MTP.

7

TUP-L

TUP, large version, up to 4096 circuits plus all MTP.

10

SCCP-CL

SCCP connectionless operation plus all MTP.

11

SCCP-CO

SCCP connection-oriented plus connectionless plus all MTP.

12

TCAP

TCAP plus SCCP-CL plus all MTP.

13

ISTC

ISUP standard version plus TCAP, plus SCCP-CL plus all MTP

14

MAP

MAP plus TCAP plus SCCP-CL plus all MTP.

15

IS41

IS41 plus TCAP plus SCCP-CL plus all MTP.