Welltech SPCI2S Intel NetStructure SS7 Boards User Manual
Page 38

SS7 Programmer’s Manual for SPCI2, SPCI4 and CPM8 Issue 2
Page 38
Parameter Description:
board_type
The type of board to be reset. This should be set to 2 for SPCI2S, SPCI4 and
CPM8 boards.
phy_id
The physical id for the board. This field should be set to the same value as the
board_id. (ie 0 .. one less than the number of boards supported).
code_file
Null terminated string giving the filename of the code file to be downloaded to
the board.
run_mode
Number taken from the following table to indicate which protocols are to be run:
NOTE: It is only possible to activate protocols that have been licensed to run on
the board by use of a suitable licence button.
run_mode
Mnemonic
Protocols selected to run on the board
1
DTI
Digital Trunk Interface only, no protocol software. This mode does
NOT require the use of a software licence button).
2
MTP2
MTP2 protocol only.
3
MTP
MTP3 plus MTP2 protocols.
4
ISUP
ISUP, standard version, up to 256 circuits plus all MTP.
5
ISUP-L
ISUP, large version, up to 4096 circuits plus all MTP.
6
TUP
TUP, standard version, up to 256 circuits plus all MTP.
7
TUP-L
TUP, large version, up to 4096 circuits plus all MTP.
10
SCCP-CL
SCCP connectionless operation plus all MTP.
11
SCCP-CO
SCCP connection-oriented plus connectionless plus all MTP.
12
TCAP
TCAP plus SCCP-CL plus all MTP.
13
ISTC
ISUP standard version plus TCAP, plus SCCP-CL plus all MTP
14
MAP
MAP plus TCAP plus SCCP-CL plus all MTP.
15
IS41
IS41 plus TCAP plus SCCP-CL plus all MTP.