beautypg.com

Welltech SPCI2S Intel NetStructure SS7 Boards User Manual

Page 82

background image

SS7 Programmer’s Manual for SPCI2, SPCI4 and CPM8 Issue 2

Page 82

5.5 Event Indication Messages

5.5.1 Board Status Indication

Synopsis:


Message sent to the application on completion of the reset and download
sequence or on detection of a board failure.

NOTE: This message is not required when using the configuration utility
s7_mgt.

Message Format:

MESSAGE HEADER

FIELD NAME

MEANING

type SSD_MSG_STATE_IND

(0x06a0)

id

board_id

src SSD_TASK_ID

(0x20)

dst

mgmt_id for SSD

rsp_req

0

hclass

0

status

0x60 - Reset successful
0x62 - Board failure

err_info

0

len

0

Description:


This message is used to convey the status of a board reset operation (whether
success of failure) to the user.

This manual is related to the following products: