beautypg.com

Welltech SPCI2S Intel NetStructure SS7 Boards User Manual

Page 75

background image

SS7 Programmer’s Manual for SPCI2, SPCI4 and CPM8 Issue 2

Page 75

5.4 MTP Interface Messages

5.4.1 MTP Link Activation Request

Synopsis:


Primitive request sent to MTP3 module to activate an SS7 signalling link.

Message Format:

MESSAGE HEADER

FIELD NAME

MEANING

type MTP_MSG_ACT_SL (0xc30a)
id linkset_id * 256 + link_ref
src

Sending Module ID

dst MTP_TASK_ID
rsp_req

used to request a confirmation

hclass

0

status

0

err_info

0

len

0

Description:


This message is issued to the level 3 module to cause a signalling link to be
activated in accordance with the procedures in Q.704.

The confirmation message (if requested) will indicate success by a status of 0.
This implies that the request for link activation has been received by MTP3 and
that activation has commenced.

Note: Receipt of the confirmation message does NOT imply that the link is
available for signalling, only that the activation procedure has commenced.

Parameter Description:

linkset_id The link set identifier


Identifies the link set in which the link is to be activated.

link_ref The link reference


Identifies which link in the link set is to be activated.