A4 TUP Parameters

A4.1 Global TUP Configuration

Syntax: TUP_CONFIG

Example: TUP_CONFIG 0 0 0x2d 0x8541 4 128

The global configuration parameters for the TUP module.

,

Reserved for backwards compatibility. These fields should be set to zero.

The module_id of the application running on the host that will use the TUP module.

A 16 bit value containing global run-time options for the operation of the TUP module. The meaning
of each bit is as defined for the ’options’ parameter in the TUP Configure Request message as
detailed in the

TUP Programmer’s Manual

The maximum number of TUP circuit groups that the user intends to use. This must not exceed the
maximum number of circuit groups supported otherwise module configuration will fail. Typically
should be set to the maximum number of circuit groups supported.

The maximum number of TUP circuits that the user intends to use. This must not exceed the
maximum number of circuits supported otherwise module configuration will fail. Typically
is set to 32 times the number of groups for E1 operation and 24 times the number of circuit groups
for T1 operation.

NOTE: The valid range for the circuit identifier (cid) is from zero up to one less than the maximum
number of circuits (num_ccts).

Optional parameter for use when operating in dual resilient configuration. This parameter is the
module_id of the ‘partner’ TUP module (equivalent to the ‘ucic_id’ field in the TUP Configure Request
message as documented in the

TUP Programmer’s Manual

).

A4.2 TUP Circuit Group Configuration

Syntax: TUP_CFG_CCTGRP

Example: TUP_CFG_CCTGRP 0 3 1 1 0x7fff7fff 0x00000003 0 0x2d 123 0x8 0 0x0

The configuration parameters for a group of TUP circuits.