SS7 Programmer’s Manual for SPCI2, SPCI4 and CPM8 Issue 2

Page 53

5.3.2 LIU Control Request

Synopsis:


Message sent by the application to dynamically control operation for a Line
Interface Unit (LIU). Allows setting of outgoing alarms and diagnostic
loopbacks.

Message Format:

MESSAGE HEADER

FIELD NAME

MEANING

type LIU_MSG_CONTROL

(0x7e35)

id

liu_id (0 .. 7)

src

Sending Module ID

dst MVD_TASK_ID (0x10)
rsp_req

used to request a confirmation

hclass

0

status

0

err_info

0

len

16

PARAMETER AREA

OFFSET SIZE

NAME

0 1 ais_gen
1 1 rai_gen
2 1 loop_mode
3

13

Reserved for future use, must be set to zero

Description:


This message is sent to the board to perform dynamic changes to the operation
of the Line Interface Unit. It allows the user to control generation of AIS (Blue
alarm) and RAI (Yellow alarm) and to activate various diagnostic loopback
modes.

The confirmation message (if requested) will indicate success by a status of 0.