3.3 Protocol Configuration

The Development Package contains a protocol configuration utility, s7_mgt which
will perform initialisation of all the software modules running on the signalling card.
It reads the protocol configuration data from a text file called config.txt and
provides a quick and flexible method of configuring the protocol modules without
the need to write any software for that purpose.

Alternatively the protocol stack may be configured by sending the individual
configuration messages documented in the per-module Programmer’s Manuals to
each protocol module. This approach is of particular use when the application
needs to reset the board and run a new configuration without stopping the
application program. It is described in a later section.

3.3.1 Protocol Configuration using the s7_mgt utility

The default configuration file used by s7_mgt is config.txt. The -k option allows the
user to specify an alternative filename if required. For example:

s7_mgt -kmyconfig.txt

The format of the configuration commands is described in Appendix A.

s7_mgt can optionally be configured to send a message to a nominated module on
completion of the configuration sequence. This option is activated using the –I
option to specify the receiving module_id as shown in the example below:

s7_mgt –i0xef

To assist problem diagnosis run s7_mgt using the –d option and additional
diagnostic output will be generated. For example:

s7_mgt –i0xef -d

3.3.2 Protocol Configuration using individual messages

As an alternative to using the s7_mgt configuration utility it is possible to carry out
protocol configuration by building and sending messages directly to the board. This
approach does mean that it is necessary to write some application code to handle
configuration but has the advantage that the application can, if required, re-configure
the board without re starting the application.

All communication with the board is in the form of sending and receiving messages.
The configuration sequence is described in the following section. The application
should allocate a message structure using the library function getm() and send it to
the board using the library function GCT_send(). The application should periodically
call the library function GCT_receive() or GCT_grab() in order to receive messages
from the board. GCT_receive() will block until a message is available whilst
GCT_grab() will return immediately. Once the application has finished processing the
received message it should release the message structure back to the system by

This manual is related to the following products: